Pelvic Imaging With a Selenium-Based Detector (Thoravision)
- 1 December 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 34 (12) , 761-6
- https://doi.org/10.1097/00004424-199912000-00005
Abstract
To evaluate whether the selenium detector (Thoravision) provides sufficient diagnostic confidence in digital pelvic imaging compared with a conventional screen-film combination. In 75 patients, pelvic imaging with conventional screen-film and isodose selenium radiography using a dedicated postprocessing mode was compared independently by three radiologists. The depiction of cortical and cancellous bone was evaluated in the iliac wings, sacral and pubic bones, acetabulum, femoral head, and trochanter. Demarcation of soft tissue was assessed in the iliac and trochanteric region. Visualization of cortical bone and soft tissue in the iliac area as well as soft tissue and cortical and cancellous bone in the trochanteric region was significantly superior with the selenium detector. However, conventional imaging was better in the trabecular bone of the sacral region, where results with the selenium system were particularly poor. The selenium detector (Thoravision) is advantageous in imaging soft tissue adjacent to the iliac wings and the trochanter, but results for the cancellous sacral bone are poor. Further modifications of postprocessing modes may lead to improved depiction of this critical pelvic area.Keywords
This publication has 27 references indexed in Scilit:
- Detection of Simulated Chest Lesions with Normal and Reduced Radiation DoseInvestigative Radiology, 1998
- Kann die digitale Selenradiographie in der Thoraxdiagnostik die analoge Röntgenaufnahmetechnik ersetzen?RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1997
- Chest radiography: depiction of normal anatomy and pathologic structures with selenium-based digital radiography versus conventional screen-film radiography.Radiology, 1997
- Digitale Röntgenthoraxaufnahmen mit einem Selendetektor: Prospektiver Vergleich mit einer konventionellen Film-Folien-KombinationRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1997
- Selenium radiography versus storage phosphor and conventional radiography in the detection of simulated chest lesions.Radiology, 1996
- Chest imaging with a selenium detector versus conventional film radiography: a CT-controlled study.Radiology, 1996
- Phantom Study of Chest Radiography with Storage Phosphor, Selenium, and Film-Screen SystemsActa Radiologica, 1996
- Technical evaluation of a digital chest radiography system that uses a selenium detector.Radiology, 1995
- X-ray imaging with amorphous selenium: Detective quantum efficiency of photoconductive receptors for digital mammographyMedical Physics, 1995
- Image quality of a digital chest radiography system based on a selenium detectorMedical Physics, 1994