Objective Criteria for Partitioning Gaussian-distributed Reference Values into Subgroups
Open Access
- 1 February 2002
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 48 (2) , 338-352
- https://doi.org/10.1093/clinchem/48.2.338
Abstract
Background: The aim of this study was to develop new and useful criteria for partitioning reference values into subgroups applicable to gaussian distributions and to distributions that can be transformed to gaussian distributions. Methods: The proposed criteria relate to percentages of the subgroups outside each of the reference limits of the combined distribution. Critical values suggested as partitioning criteria for these percentages were derived from analytical bias quality specifications for using common reference intervals throughout a geographic area. As alternative partitioning criteria to the actual percentages, these were transformed mathematically to critical distances between the reference limits of the subgroup distributions, to be applied to each pair of reference limits, the upper and the lower, at a time. The new criteria were tested using data on various plasma proteins collected from ∼500 reference individuals, and the outcomes were compared with those given by the currently widely applied and recommended partitioning model of Harris and Boyd, the “Harris-Boyd model”. Results: We suggest 4.1% as the critical minimum percentage outside that would justify partitioning into subgroups, and 3.2% as the critical maximum percentage outside that would justify combining them. Percentages between these two values should be classified as marginal, implying that nonstatistical considerations are required to make the final decision on partitioning. The correlation between the critical percentages and the critical distances was mathematically precise in the new model, whereas this correlation is rather approximate in the Harris-Boyd model because focus on the difference between means in this model makes high precision hard to achieve. The application examples suggested that the new model is more radical than the Harris-Boyd model. Conclusions: New percentage and distance criteria, to be used for partitioning gaussian-distributed data, have been developed. The distance criteria, applied separately to both reference limit pairs of the subgroup distributions, seemed more reliable and correlated more accurately with the critical percentages than the distance criteria of the Harris-Boyd model. As opposed to the Harris-Boyd model, the new model is easily adjustable to new critical values of the percentages, should they need to be changed in the future.Keywords
This publication has 15 references indexed in Scilit:
- Optimization of preanalytical conditions and analysis of plasma glucose. 1. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitusScandinavian Journal of Clinical and Laboratory Investigation, 2001
- Plasma glucose reference intervalin a low-risk population. 2. Impact ofthe new WHO and ADA recommendations on the diagnosis of diabetes mellitusScandinavian Journal of Clinical and Laboratory Investigation, 2001
- Need for Revisiting the Concept of Reference Valuescclm, 2000
- Immunoradiometric Assay of Circulating C-Reactive Protein: Age-related Values in the Adult General PopulationClinical Chemistry, 2000
- Analytical Quality Specifications for Serum Lactate Dehydrogenase Isoenzyme 1 Based on Clinical Goalscclm, 1999
- Reference distributions for immunoglobulins A, G, and M: A practical, simple, and clinically relevant approach in a large cohortJournal of Clinical Laboratory Analysis, 1998
- Proposals for Setting Generally Applicable Quality Goals Solely Based on BiologyAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1997
- Analytical Goals for the Estimation of Non-Gaussian Reference IntervalsScandinavian Journal of Clinical and Laboratory Investigation, 1989
- Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical areaScandinavian Journal of Clinical and Laboratory Investigation, 1988
- Early observations of S-myoglobin in the diagnosis of acute myocardial infarction. The influence of discrimination limit, analytical quality, patient's sex and prevalence of diseaseScandinavian Journal of Clinical and Laboratory Investigation, 1985