Cardiovascular Circulation and Hepatic Perfusion of Pigs in 4-Dimensional Films Evaluated by 256-Slice Cone-Beam Computed Tomography
Open Access
- 1 January 2005
- journal article
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 69 (5) , 585-589
- https://doi.org/10.1253/circj.69.585
Abstract
Background In both cardiac and hepatic disorders it is desirable to accurately visualize the direction and scale of blood flow in the whole organ in pulsating 3-dimensional (D) images, which are known as 4-D images. Methods and Results The present study used 256-slice cone-beam computed tomography (CT) (Athena, Sony-Toshiba) at one rotation per second and a section thickness of 0.5 mm to show the dynamics of cardiovascular circulation and hepatic perfusion by contrast injection in 4-D films of pigs. Four pigs (20 kg each) were anesthetized with isoflurane. The distal tips of the catheters were positioned in the inferior vena cava (IVC) (pigs 1-3) and in the proper hepatic artery (pig 4). Volumetric scanning and injection of contrast material were started simultaneously and continued for 25 s with image reconstruction at 1-s intervals. In pigs 1-3, 4-D filming revealed the dynamics of cardiovascular circulation, first in the IVC, followed by the right ventricle and pulmonary artery, then the left ventricle, left atrium, pulmonary vein, and finally, the right heart disappeared and only the left heart and aorta remained visible. In pig 4, the hepatic arterial trees, followed by the venous trees, could be easily visualized in turn on the 4-D images. Conclusions This technology successfully demonstrated cardiovascular circulation and hepatic perfusion in 4-D and will have clinical applicability. (Circ J 2005; 69: 585 - 589)Keywords
This publication has 24 references indexed in Scilit:
- Physical performance evaluation of a 256-slice CT-scanner for four-dimensional imagingMedical Physics, 2004
- Acute Effects of Diltiazem on Regional Left Ventricular Diastolic Filling Dynamics in Patients With Hypertrophic Cardiomyopathy as Assessed by Color KinesisCirculation Journal, 2004
- Development and performance evaluation of the first model of 4-D CT-scannerIEEE Transactions on Nuclear Science, 2003
- Decreased Left Atrial Appendage Flow Velocity With Atrial Fibrillation Caused by Negative Inotropic Agents. Report of 2 Cases.Circulation Journal, 2003
- Measuring Portal Venous Perfusion with Contrast-Enhanced CT: Comparison of Direct and Indirect MethodsAcademic Radiology, 2002
- Hepatic haemodynamics: interrelationships between contrast enhancement and perfusion on CT and Doppler perfusion indicesThe British Journal of Radiology, 2002
- Early Changes in Liver Perfusion Caused by Occult Metastases in Rats: Detection with Quantitative CTRadiology, 2001
- Qualitative Blood Flow DifferentiationJapanese Circulation Journal, 2000
- A Pitfall in Ultrafast CT Scanning for the Detection of Left Atrial ThrombiJournal of Computer Assisted Tomography, 1993
- Abnormal blood pathways in left ventricular cavity in acute myocardial infarction. Experimental observations with special reference to regional wall motion abnormality and hemostasis.Circulation, 1988