The performance of a diode array (Profiler) was evaluated by comparing its enhanced dynamic wedge (EDW) profiles measured at various depths with point measurements using a ionization chamber on a commercial linear accelerator. The Profiler, which covers a 22.5 cm width, was used to measure larger field widths by concatenating three data sets into a larger field. An innovative wide‐field calibration technique developed by the manufacturer of the device was used to calibrate the individual diode sensitivity, which can vary by more than 10%. Profiles of EDW measured with this device at several depths were used to construct isodose curves using the percentage depth dose curve measured by the ionization chamber. These isodose curves were used to check those generated by a commercial treatment planning system. The profiles measured with the diode array for both 8 and 18 MV photon beams agreed with those of the ionization chamber within a standard deviation of 0.4% in the field (defined as 80% of the field width) and within a maximum shift of less than 2 mm in the penumbra region. The percentage depth dose generally agreed to within 2% except in the buildup region. The Profiler was extremely useful as a quality assurance tool for EDW and as a dosimetry measurement device with tremendous savings in data acquisition time.Keywords
This publication has 13 references indexed in Scilit:
- Implementation of the Varian EDW into a commercial RTP systemPhysics in Medicine & Biology, 1996
- An investigation into the comparison between different dosimetric methods of measuring profiles and depth doses for dynamic wedges on a Varian 600C linear acceleratorPhysics in Medicine & Biology, 1995
- Beam data measurements for dynamic wedges on Varian 600C (6 MV) and 2100C (6 and 10 MV) linear acceleratorsPhysics in Medicine & Biology, 1995
- Dosimetry and clinical implementation of dynamic wedgeInternational Journal of Radiation Oncology*Biology*Physics, 1995
- Evaluation of a diode detector array for measurement of dynamic wedge dose distributionsMedical Physics, 1993
- Dynamic Beam ShapingMedical Dosimetry, 1990
- Dynamic wedge field techniques through computer‐controlled collimator motion and dose deliveryMedical Physics, 1990
- Effective wedge angles with a universal wedgePhysics in Medicine & Biology, 1985
- Wedge-shaped dose distributions by computer-controlled collimator motionMedical Physics, 1978
- Program IRREG — Calculation of dose from irregularly shaped radiation beamsComputer Programs in Biomedicine, 1972