Effects of Positive End-expiratory Pressure, Lung Volume, and Inspiratory Flow on Interrupter Resistance in Patients with Adult Respiratory Distress Syndrome
- 1 September 1991
- journal article
- Published by American Thoracic Society in American Review of Respiratory Disease
- Vol. 144 (3) , 538-543
- https://doi.org/10.1164/ajrccm/144.3_pt_1.538
Abstract
Although it has been shown in normal subjects that airway resistance changes significantly with changes in lung volume and inspiratory flow, no studies have as yet examined these phenomena in patients with adult respiratory distress syndrome (ARDS). The effect of positive end-expiratory pressure (PEEP) on airway resistance in ARDS also is unknown. We have used the technique of rapid airway occlusion during constant-flow inflation to measure the interrupter resistance (Rint,rs), which in humans is thought to correspond to airway resistance, in nine patients with ARDS under different inflation flows and volumes. This procedure was carried out at four levels of PEEP (0, 5, 10, and 15 cm H2O). We found that (1) at constant inflation volume, Rint,rs did not change significantly with increasing flow; (2) at constant inflation flow, Rint,rs showed an initial decrease followed by a distinct rise with increasing lung volume; (3) on average, PEEP did not significantly change Rint,rs measured during baseline ventilation; and (4) this latter finding occurred because patients behaved differently with application of PEEP, depending on their degree of lung inflation: Rint,rs measured close to full inflation almost invariably exhibited a rise, but values obtained at lower volumes exhibited the characteristic decrease of Rint,rs with increasing inflation volume.Keywords
This publication has 13 references indexed in Scilit:
- The prediction of pressure drop and variation of resistance within the human bronchial airwaysPublished by Elsevier ,2003
- Interpretation of interrupter resistance after histamine-induced constriction in the dogJournal of Applied Physiology, 1990
- Respiratory mechanics in anesthetized paralyzed humans: effects of flow, volume, and timeJournal of Applied Physiology, 1989
- Interrupter resistance elucidated by alveolar pressure measurement in open-chest normal dogsJournal of Applied Physiology, 1988
- Alveolar pressure nonhomogeneity during small-amplitude high-frequency oscillationJournal of Applied Physiology, 1984
- Early Application of Positive End-Expiratory Pressure in Patients at Risk for the Adult Respiratory-Distress SyndromeNew England Journal of Medicine, 1984
- The Relationship Between Airway Resistance, Airway Conductance and Lung Volume in Subjects of Different Age and Body Size12Journal of Clinical Investigation, 1958
- A NEW METHOD FOR MEASURING AIRWAY RESISTANCE IN MAN USING A BODY PLETHYSMOGRAPH: VALUES IN NORMAL SUBJECTS AND IN PATIENTS WITH RESPIRATORY DISEASE 1Journal of Clinical Investigation, 1956
- A Multiple Comparison Procedure for Comparing Several Treatments with a ControlJournal of the American Statistical Association, 1955
- A METHOD FOR THE DEMONSTRATION OF CALIBRE CHANGES IN THE BRONCHI IN NORMAL RESPIRATIONJournal of Clinical Investigation, 1927