Glucose monitoring using implanted fluorescent microspheres
- 1 January 2000
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Engineering in Medicine and Biology Magazine
- Vol. 19 (6) , 36-45
- https://doi.org/10.1109/51.887244
Abstract
The authors are working toward a minimally invasive means for diabetics to better monitor glucose levels. A fiber-optic probe was fabricated for delivery and collection of light to an implanted sensor. The probe and associated optical system has high sensitivity and allows for flexible, remote measurements. The system was used to collect data with sensor solutions similar to what is envisioned for the implantable system, and the recorded spectra were processed in an attempt to predict glucose concentrations from fluorescence measurements. Despite the availability of sophisticated multivariate calibration methods, the best prediction results were obtained using polynomial regression with regression coefficient ratios. The measurements are far from perfect, but they do meet the requirements for clinical use and show promise for further improvement in the future. In vivo experiments were conducted using "simulated" sensors that had constant fluorescence characteristics. Results of implantation in excised skin and in live animals indicate that, while very strong fluorescence signals were measured for implanted particles, the current sensor chemistry must be improved for adequate resolution. In addition, difficulty in achieving repeatable injection depths and homogeneity of mixtures containing different colored spheres confounded attempts to make true quantitative measurements.Keywords
This publication has 21 references indexed in Scilit:
- Monte Carlo modeling for implantable fluorescent analyte sensorsIEEE Transactions on Biomedical Engineering, 2000
- A Transparent Tool for Seemingly Difficult Calibrations: The Parallel Calibration MethodAnalytical Chemistry, 1999
- A novel peak-hopping stepwise feature selection method with application to Raman spectroscopy1This paper is dedicated to the memory of Jean Thomas Clerc: scientist, editor, luminary, and dog breeder.1Analytica Chimica Acta, 1999
- Theoretical Justification of Wavelength Selection in PLS Calibration: Development of a New AlgorithmAnalytical Chemistry, 1998
- Optical assay for glucose based on the luminescnence decay time of the long wavelength dye Cy5™Sensors and Actuators B: Chemical, 1997
- Variable Selection in Multivariate Calibration of a Spectroscopic Glucose SensorApplied Spectroscopy, 1997
- Competitive-binding assay method based on fluorescence quenching of ligands held in close proximity by a multivalent receptorAnalytica Chimica Acta, 1997
- Design, manufacture and characterization of an optical fiber glucose affinity sensor based on an homogeneous fluorescence energy transfer assay systemAnalytica Chimica Acta, 1993
- Optical sensing of glucose using phase-modulation fluorimetryAnalytica Chimica Acta, 1993
- Fiber-optic biosensors based on fluorescence energy transferTalanta, 1988