Timing of Vertebral Registration in Three-dimensional, Fluoroscopy-based, Image-guided Spinal Surgery
- 1 July 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 22 (5) , 358-360
- https://doi.org/10.1097/bsd.0b013e31817dfcda
Abstract
Study Design The timing of vertebral registration using isocentric fluoroscopy was recorded in 20 consecutive patients undergoing image-guided spinal surgery. Objective To determine if vertebral registration in three-dimensional, fluoroscopy-based, image-guided spinal surgery can be performed in an efficient manner. Summary of Background Data Many spine surgeons are reluctant to incorporate spinal image guidance into their surgical practice due to the perception that it is time consuming and tedious, especially the task of vertebral registration. The authors evaluated the time required for vertebral level registration using the Arcadis Orbic isocentric C-arm (Siemens Medical Solutions, Erlangen, Germany) in conjunction with the BrainLAB (BrainLAB, Westchester, IL) image-guided system for spinal surgery cases. Methods The time required to register vertebral segments using the isocentric C-arm was assessed in 20 consecutive patients undergoing spinal fusions by the senior author (E.W.N.). Overall, 80 vertebral segments spanning from C1 to S1 were registered with 23 spins of the isocentric C-arm. Timing was started when the surgeon began to place the image-guided reference arc on the spine and commenced when the spine could be navigated using the image-guided system. Results The average time required for this process was 8 minutes and 34 seconds per patient. No complications occurred in this study as a result of instrumentation placement or the use image guidance. Excellent navigation accuracy was obtained in all cases and no malfunction of the isocentric C-arm or image-guided system occurred. Postoperative radiographic studies were performed on all patients and revealed adequate placement of instrumentation. Conclusions The use of the isocentric C-arm for vertebral registration in image-guided spinal surgery can be performed in an efficient manner. In this study, multiple vertebral levels of registration could be accomplished in less than 9 minutes with minimal to no radiation exposure to the surgeon and operating room personnel.Keywords
This publication has 8 references indexed in Scilit:
- Computer-assisted Spinal Navigation Versus Serial Radiography and Operative Time for Posterior Spinal Fusion at L5-S1Journal of Spinal Disorders & Techniques, 2007
- Randomized Clinical Study to Compare the Accuracy of Navigated and Non-Navigated Thoracic Pedicle Screws in Deformity Correction SurgeriesSpine, 2007
- Intraoperative Iso-C C-arm Navigation in Cervical Spinal SurgerySpine, 2004
- Electromagnetic Field-Based Image-Guided Spine Surgery Part One: Results of a Cadaveric Study Evaluating Lumbar Pedicle Screw PlacementSpine, 2003
- Transpedicular Screw PlacementSpine, 2001
- Radiation Exposure to the Spine Surgeon During Fluoroscopically Assisted Pedicle Screw InsertionSpine, 2000
- Placement of pedicle screws in the thoracic spine. Part IIJournal of Bone and Joint Surgery, 1995
- Accuracy of Pedicular Screw Placement In VivoSpine, 1990