A computational method is presented to analyze the worst case sensitivity of electrical networks over a band of frequencies. The method uses nonlinear programming techniques to find the maxima and minima of a network function at discrete frequencies within the frequency interval over the entire element constraint space in order to calculate the sensitivity.

This publication has 2 references indexed in Scilit: