Pediatric perfusion imaging using pulsed arterial spin labeling
Open Access
- 19 September 2003
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 18 (4) , 404-413
- https://doi.org/10.1002/jmri.10372
Abstract
Purpose To test the feasibility of pediatric perfusion imaging using a pulsed arterial spin labeling (ASL) technique at 1.5 T. Materials and Methods ASL perfusion imaging was carried out on seven neurologically normal children and five healthy adults. The signal‐to‐noise ratio (SNR) of the perfusion images along with T1, M0, arterial transit time, and the temporal fluctuation of the ASL image series were measured and compared between the two age groups. In addition, ASL perfusion magnetic resonance (MR) was performed on three children with neurologic disorder. Results In the cohort of neurologically normal children, a 70% increase in the SNR of the ASL perfusion images and a 30% increase in the absolute cerebral blood flow compared to the adult data were observed. The measures of ASL SNR, T1, and M0 were found to decrease linearly with age. Transit time and temporal fluctuation of the ASL perfusion image series were not significantly different between the two age groups. The feasibility of ASL in the diagnosis of pediatric neurologic disease was also illustrated. Conclusion ASL is a promising tool for pediatric perfusion imaging given the unique and reciprocal benefits in terms of safety and image quality. J. Magn. Reson. Imaging 2003;18:404–413.Keywords
This publication has 27 references indexed in Scilit:
- Magnetic Resonance Perfusion Imaging in Acute Ischemic Stroke Using Continuous Arterial Spin LabelingStroke, 2000
- Assessment of cerebral blood flow in Alzheimer's disease by spin-labeled magnetic resonance imagingAnnals of Neurology, 2000
- Stages of increased cerebral blood flow accompany stages of rapid brain growthBrain & Development, 1999
- Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular diseaseNeurology, 1998
- Age-specific cerebral perfusion in 4- to 15-year-old children: a high-resolution brain SPET study using 99mTc-ECD.European Journal of Nuclear Medicine and Molecular Imaging, 1997
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996
- Age Dependence of Total Cerebral Blood Flow Volume from Childhood to AdulthoodJournal of Cerebral Blood Flow & Metabolism, 1996
- Tissue specific perfusion imaging using arterial spin labelingNMR in Biomedicine, 1994
- Regional cerebral blood flow with age: changes in rCBF in childhoodNeurological Research, 1989
- Maturational Changes in Cerebral Function in Infants Determined by 18 FDG Positron Emission TomographyScience, 1986