Continuously Recorded Changes of Thoracic Aortic Blood Flow in Man in Response to Leg Exercise in Supine Position
- 1 August 1965
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation Research
- Vol. 17 (2) , 97-105
- https://doi.org/10.1161/01.res.17.2.97
Abstract
The constant-rate-injection, indicator-dilution technic was used to determine thoracic aortic blood flow before, during, and after five minutes of single-leg exercise (bicycle ergometer) in five healthy male subjects in the supine position. Resistance to blood flow in the lower body and mean aortic pressure decreased immediately at the onset of exercise, at the same time that thoracic aortic blood flow and heart rate increased. There was a further slow rise of heart rate, mean aortic pressure, and thoracic aortic blood flow along with a decrease of lower body resistance until fairly stable levels were reached after five minutes of exercise. After five and ten minutes' rest all values tended to return toward those observed in the control state. These data are consistent with the concept that baroreceptor activity may play an important part in the early cardiovascular responses to exercise in man. Most of the cardiovascular response to this exercise occurred in the first 30 seconds.Keywords
This publication has 12 references indexed in Scilit:
- Carotid sinus baroceptor modifications associated with endotoxin shockAmerican Journal of Physiology-Legacy Content, 1962
- THE EFFECT OF CHANGES IN POSTURE AND OF GRADED EXERCISE ON STROKE VOLUME IN MAN *Journal of Clinical Investigation, 1960
- PROPERTIES AND BIOLOGICAL BEHAVIOUR OF COOMASSIE BLUEHeart, 1959
- Thoracic-Aorta Flow in ManJournal of Applied Physiology, 1957
- Hemodynamic Response of Healthy Subjects to Exercise in the Supine Position While Breathing OxygenJournal of Applied Physiology, 1957
- The Cardiac Output in Rest and Work Determined Simultaneously by the Acetylene and the Dye Injection Methods.Acta Physiologica Scandinavica, 1953
- Effect of Exercise on Circulatory Dynamics of Normal IndividualsJournal of Applied Physiology, 1951
- Special Instrumentation Problems Encountered in Physiological Research Concerning the Heart and Circulation in ManScience, 1950
- THE PULMONARY CIRCULATION TIME, THE QUANTITY OF BLOOD IN THE LUNGS AND THE OUTPUT OF THE HEARTAmerican Journal of Physiology-Legacy Content, 1921
- CHANGES IN HEART-RATE, BLOOD-PRESSURE, AND DURATION OF SYSTOLE RESULTING FROM BICYCLINGAmerican Journal of Physiology-Legacy Content, 1904