Relative Error (Variability) Associated With an Improved Instrument for Measuring Gingival Crevicular Fluid
- 1 May 1984
- journal article
- research article
- Published by Wiley in The Journal of Periodontology
- Vol. 55 (5) , 294-298
- https://doi.org/10.1902/jop.1984.55.5.294
Abstract
This investigation was undertaken to compare the variability in a new Periotron model 6000 to the variability in the previous Periotron model 600 and to the variability of the ninhydrin area method (NAM) for measuring quantities of fluid collected on filter paper strips. A Hamilton microliter syringe was used to deliver normal human serum to filter paper strips. Strips receiving varying quantities were randomly and blindly assigned to Periotron models 6000 and 600 until 10 strips containing each of 0.15, 0.30, 0.45, 0.60, 0.75, 0.90 and 1.05 microliter had been read using model 6000 and 10 strips containing each of 0.15, 0.30 and 0.45 microliter had been read using model 600. All strips were subsequently read using the NAM. The entire procedure was repeated using distilled water containing 0.1% methyl green. Coefficients of variation (CV) were computed for all sets of data. In all cases the CVs for the Periotron 6000 were significantly smaller than those for the Periotron 600 or the NAM. Pooled estimates of CVs (0.15-0.45 microliter) for the Periotron models 6000 and 600 were 0.054 and 0.116, respectively, (P less than or equal to 0.005) with serum and 0.059 and 0.095, respectively, (P less than or equal to 0.05) with distilled water containing 0.1% methyl green. Pooled estimates of CVs (0.15-1.05 microliter) for the Periotron model 6000 and the same strips subsequently measured with the NAM were 0.046 and 0.069, respectively, (P less than or equal to 0.005) with serum and 0.055 and 0.076, respectively, (P less than or equal to 0.001) with distilled water containing 0.1% methyl green.(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 16 references indexed in Scilit:
- The use of selective media for examining relationships between dental plaque microorganisms and periodontal disease in a large sample clinical investigationJournal of Periodontal Research, 1982
- The Evaluation of the PeriotronThe Journal of Periodontology, 1979
- Evaluation of an Electronic Device for Gingival Fluid QuantitationThe Journal of Periodontology, 1977
- Correlation between gingival fluid measurements and macroscopic and microscopic characteristics of gingival tissueJournal of Periodontal Research, 1976
- The Correlation Between Clinical Scoring, Exudate Measurements and Microscopic Evaluation of Inflammation in the GingivaJournal of Periodontology-Periodontics, 1969
- Gingival Crevicular Fluid: A Reliable Predictor of Gingival Health?Journal of Periodontology-Periodontics, 1969
- The Relative Proportions of Sodium, Potassium and Calcium in Gingival Pocket FluidActa Odontologica Scandinavica, 1962
- Gingival Conditions Related to Flow of Tissue Fluid Into Gingival PocketsActa Odontologica Scandinavica, 1960
- Passage of Tissue Fluid Into Human Gingival PocketsActa Odontologica Scandinavica, 1959