Abstract
To evaluate the interdevice reproducibility of retinal nerve fibre layer (RNFL) thickness measurements obtained with the commercially available GDx-VCC, a scanning laser polarimeter with variable (individualized) corneal compensation. A prospective instrument validation study in which 13 GDx-VCC devices were tested. One eye each, from three normal subjects were used to test each of the devices, on the same day, by an experienced operator. Variability and reproducibility for each of five GDx parameters were calculated. For each of five tested GDx parameters, the coefficient of variation and 95% confidence interval range (μm), for the 13 devices, respectively, were: TSNIT avg: 5.1%, 3.84 μm; Superior avg: 5.3%, 4.82 μm; Inferior avg: 6.1%, 5.50 μm; TSNIT standard deviation: 8.6%, 2.92 μm; and nerve fibre indicator (NFI): N/A, 5.69. Item reliability (Cronbach's alpha) for the five GDx parameters are: TSNIT-Avg: 0.97, Sup-Avg: 1.00, Inf-Avg: 0.84, TSNIT-SD: 0.99, NFI: 0.99. With the commercially available GDx-VCC, our results indicate that RNFL measurements appear reproducible across devices.Keywords
This publication has 15 references indexed in Scilit:
- Correction for corneal polarization axis improves the discriminating power of scanning laser polarimetryAmerican Journal of Ophthalmology, 2002
- Measurement of the magnitude and axis of corneal polarization with scanning laser polarimetry.Archives of Ophthalmology (1950), 2002
- Effects of cataract extraction with intraocular lens placement on scanning laser polarimetry of the peripapillary nerve fiber layerAmerican Journal of Ophthalmology, 2001
- Assessment of the Retinal Nerve Fiber Layer in Clinical Trials of Glaucoma NeuroprotectionSurvey of Ophthalmology, 2001
- Reproducibility of scanning laser polarimetry (GDx) of peripapillary retinal nerve fiber layer thickness in normal subjectsAlbrecht von Graefes Archiv für Ophthalmologie, 2001
- Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetryAmerican Journal of Ophthalmology, 2000
- Scanning laser polarimetry measurements after laser-assisted in situ keratomileusisAmerican Journal of Ophthalmology, 2000
- Evaluation of the retinal nerve fiber layerSurvey of Ophthalmology, 1996
- Histopathologic Validation of Fourier-Ellipsometry Measurements of Retinal Nerve Fiber Layer ThicknessArchives of Ophthalmology (1950), 1990
- Standardized EchographyInternational Ophthalmology Clinics, 1979