Abstract
The Ag–Ca system has been reinvestigated over the composition range 50–100 atomic % Ca, by differential thermal analysis and high temperature X-ray powder diffraction. Our results are in good agreement with those of Alexander et al. (1) and those of Pascal et al. (2) in the region 50–59 atomic % Ca, but the peritectic claimed by Alexander et al., lying at 50% Ca and 598 °C, appears not to exist, according to our DTA and X-ray results. Here and elsewhere our results substantiate those of Pascal et al. We also find that the compound AgCa3 is formed peritectically, and not congruently as suggested by Alexander et al.