X-Ray Study of Cold Work in Molybdenum
- 1 February 1958
- journal article
- research article
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 29 (2) , 195-197
- https://doi.org/10.1063/1.1723066
Abstract
Filings from a molybdenum rod, pressed into a briquet, were used as the cold worked sample. Satisfactory peak shapes for 110, 200, 211, 220, and 310 were obtained with filtered CuKα. Peak shapes for 400 and 422 obtained with filtered MoKα were not satisfactory, partly because of fluorescence radiation. Peaks were recorded with a Norelco diffractometer, and instrumental broadening corrected by the Stokes method. The Fourier coefficients indicate approximately isotropic incoherent domains L=260 A, and strains inversely as Young's modulus. Molybdenum is similar to tungsten in that there is no evidence for faulting on (211) as a result of cold work.This publication has 6 references indexed in Scilit:
- X-Ray Study of Faults in Body-Centered Cubic MetalsJournal of Applied Physics, 1958
- The use of Fourier analysis in the interpretation of X-ray line broadening from cold-worked iron and molybdenumActa Crystallographica, 1954
- X-Ray Study of Cold Work in Thoriated TungstenJournal of Applied Physics, 1953
- The Separation of Cold-Work Distortion and Particle Size Broadening in X-Ray PatternsJournal of Applied Physics, 1952
- A Numerical Fourier-analysis Method for the Correction of Widths and Shapes of Lines on X-ray Powder PhotographsProceedings of the Physical Society, 1948
- Die elastische anisotropie von molybdänPhysica, 1941