Abstract
Physiological hand tremor impedes microsurgery. We present both a novel adaptive algorithm for tremor estimation and a new technique for active real-time cancelling of physiological tremor. Tremor is modeled online using the weighted-frequency Fourier linear combiner (WFLC). This adaptive algorithm models tremor as a modulating sinusoid, and tracks its frequency, amplitude and phase. Piezoelectric actuators move the surgical instrument tip in opposition to the motion of tremor, effectively subtracting the tremor from the total motion. We demonstrate the technique in 1D using a cantilever apparatus as a benchtop simulation of the surgical instrument. Actual hand motion, prerecorded during simulated surgery, is used as input. In 25 tests, WFLC tremor compensation reduces the RMS tip motion in the 6-16 Hz tremor band by 67%, and reduces the RMS error with respect to an a posteriori estimate of voluntary motion by 30%. The technique can be implemented in a hand-held microsurgical instrument.Keywords
This publication has 13 references indexed in Scilit:
- Adaptive cancelling of physiological tremor for improved precision in microsurgeryIEEE Transactions on Biomedical Engineering, 1998
- Modeling and canceling tremor in human-machine interfacesIEEE Engineering in Medicine and Biology Magazine, 1996
- An adaptive estimation of periodic signals using a Fourier linear combinerIEEE Transactions on Signal Processing, 1994
- A Teleoperated Microsurgical Robot and Associated Virtual Environment for Eye SurgeryPRESENCE: Virtual and Augmented Reality, 1993
- Tremor compensation for robotics assisted microsurgeryPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1992
- Spectral analysis of tremor: understanding the results.Journal of Neurology, Neurosurgery & Psychiatry, 1990
- Adaptive Fourier estimation of time-varying evoked potentialsIEEE Transactions on Biomedical Engineering, 1989
- A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgeryIEEE Transactions on Biomedical Engineering, 1988
- Distributed piezoelectric-polymer active vibration control of a cantilever beamJournal of Guidance, Control, and Dynamics, 1985
- ERGONOMICS APPLIED TO THE PRACTICE OF MICROSURGERY1Anz Journal of Surgery, 1977