Factors affecting and methods of improving the pulse repetition frequency of pulse-charged and DC-charged high-pressure gas switches
- 1 April 1997
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 25 (2) , 110-117
- https://doi.org/10.1109/27.602480
Abstract
The results of this paper describe some of the factors which affect the repetitive operation of high-pressure gas switches (spark gaps) for both pulse-charged and DC-charged operation. Also discussed are methods which may be employed to improve the pulse repetition frequency (PRF) of spark gaps operating under such conditions. Under pulse-charged conditions, the voltage recovery process of the spark gap has been shown to be restricted following partial density recovery by the residual ion population. This restriction may be minimized by applying a suitable bias voltage across the gap to remove the ion influence. It is also possible to manipulate the voltage-pressure (V-p) breakdown characteristic of a spark gap in order to improve the rate of rise of recovery voltage by reducing the recovery voltage dependence upon gas pressure. The combination of these effects has been shown to reduce the voltage recovery time of pulse-charged spark gaps from several hundred milliseconds to several milliseconds. Under DC-charged conditions, where no \"dead time\" is available for voltage recovery, it is possible to employ corona discharge effects, which occur in highly nonuniform fields, to stabilize and control the breakdown process. The use of corona stabilization has enabled the operation of a self-closing spark gap at a PRF of more than 5 kHz, without employing gas flow techniques. A triggered version of a corona-stabilized spark gap has also been developed which has demonstrated single run capabilities of 10/sup 7/ (4 h continuous operation at 700 pps) and a lifetime of /spl sim/10 shots (maintenance free, sealed switch). The triggered corona switch has also demonstrated controlled switching up to a PRF of 1.2 kHz.Keywords
This publication has 8 references indexed in Scilit:
- A 100 kV, 1 kHz triggered pulse generatorPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- A high PRF pulsed power experimental facilityPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Enhanced spark gap switch recovery using nonlinear V/p curvesIEEE Transactions on Plasma Science, 1995
- A novel HV double pulse modulatorMeasurement Science and Technology, 1994
- A quantitative laser schlieren method for measurement of neutral gas density in high-pressure gas switchesMeasurement Science and Technology, 1993
- The operation of repetitive high-pressure spark gap switchesJournal of Physics D: Applied Physics, 1993
- High-repetition-rate hydrogen spark gapIEEE Transactions on Electron Devices, 1991
- An efficient stacked-Blumlein HV pulse generatorMeasurement Science and Technology, 1990