A comparison of 266 nm, 213 nm and 193 nm produced from a single solid state Nd:YAG laser for laser ablation ICP-MS
Top Cited Papers
- 29 July 2003
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 18 (10) , 1224-1230
- https://doi.org/10.1039/b305434a
Abstract
Laser ablation using wavelengths of 266 nm, 213 nm and 193 nm as a sampling method for ICP-MS was compared. Unlike previous studies, this was performed under essentially identical laser ablation conditions with the exception of wavelength. This was achieved by using a single solid state laser source (1064 nm Nd:YAG) for harmonic generation together with sum frequency mixing and optical parametric oscillation. Experiments were carried out on the NIST 600 series silicate glasses. Particle size distributions for all three wavelength were measured and increased in the order 193 nm < 213 nm < 266 nm. This effect is related to the absorption behaviour of the sample opaque < transparent at each wavelength. The change towards larger particle sizes with increasing wavelength is influencing the noise in the transient signals and their intensity ratios. A smaller number of particles with diameters of >150 nm are produced in comparison to longer wavelengths when ablating with 193 nm. Due to the decreased amount of particles above 0.15 µm vaporisation induced elemental fractionation within the ICP, especially for more transparent samples is reduced. Data on the behaviour of 213 nm ablation and resulting ICP-MS response demonstrated that this wavelength is intermediate between 193 nm and 266 nm, but biased towards 193 nm for more opaque samples and biased towards 266 nm for those more transparent. This study (maintaining laser parameter constant and not exceeding depth to diameter ratios of 2∶1) shows that the wavelengths in first instance are responsible for particle size distribution and that their distribution leads to enhanced vaporisation, atomisation and ionisation effects within the ICP. Until now, only 193 nm produced particle sizes (as shown for the selection of silicate samples) can be stoichiometrically converted into ions using common ICP-MS instruments.Keywords
This publication has 39 references indexed in Scilit:
- Laser ablation in analytical chemistry—a reviewTalanta, 2002
- Recent trends and developments in laser ablation-ICP-mass spectrometryAnalytical and Bioanalytical Chemistry, 2000
- Laser ablation and arc/spark solid sample introduction into inductively coupled plasma mass spectrometersSpectrochimica Acta Part B: Atomic Spectroscopy, 1999
- Laser ablation inductively coupled plasma mass spectrometry: achievements, problems, prospectsJournal of Analytical Atomic Spectrometry, 1999
- Elemental Fractionation of Glass Using Laser Ablation Inductively Coupled Plasma Mass SpectrometryApplied Spectroscopy, 1997
- Laser Induced Plasma Spectroscopy: Α Review of Recent AdvancesReviews in Analytical Chemistry, 1997
- Chemical fractionation during infrared and ultraviolet laser ablation inductively coupled plasma mass spectrometry—implications for mineral microanalysisAnalytical Communications, 1996
- Comparisons of infrared and ultraviolet laser probe microanalysis inductively coupled plasma mass spectrometry in mineral analysisThe Analyst, 1995
- Comparison between infrared and ultraviolet laser ablation at atmospheric pressure—implications for solid sampling inductively coupled plasma spectrometryJournal of Analytical Atomic Spectrometry, 1994
- Solid sample introduction by laser ablation for inductively coupled plasma source mass spectrometryThe Analyst, 1985