Abstract
Undersampled projection reconstruction (PR) offers improved imaging efficiency allowing a relative tradeoff between signal-to-noise ratio (SNR) or streak artifact and the number of acquired k-space views rather than the tradeoff between resolution or aliasing artifact and the number of acquired k-space lines inherent to Fourier imaging techniques. TrueFISP (true fast imaging with steady state precession) is ideally suited for undersampled PR imaging because of its inherently high SNR. The purpose of this work was to investigate the feasibility of using undersampled three-dimensional (3D) PR TrueFISP for breathhold coronary artery imaging. Phantom studies and a preliminary in vivo comparison demonstrated the improved spatial resolution of PR over Fourier TrueFISP with the same imaging time. In a 24-heartbeat coronary imaging scheme, segmented 3D PR TrueFISP provided a 1.0 × 1.0 mm2 isotropic in-plane voxel size while acquiring between 93 and 153 views per partition. Streak artifacts were present in some images but were not found to impede coronary artery delineation. In conclusion, 3D undersampled PR TrueFISP provides isotropic in-plane voxel size within a single breathhold and is a promising technique for coronary artery imaging. Magn Reson Med 48:594–601, 2002.Keywords
This publication has 21 references indexed in Scilit:
- Breath‐hold three‐dimensional true‐FISP imaging of coronary arteries using asymmetric samplingJournal of Magnetic Resonance Imaging, 2002
- Segmented k-Space and Real-Time Cardiac Cine MR Imaging with Radial TrajectoriesRadiology, 2001
- 3D magnetization‐prepared true‐FISP: A new technique for imaging coronary arteriesMagnetic Resonance in Medicine, 2001
- Cine MR Angiography of the Heart with Segmented True Fast Imaging with Steady-State PrecessionRadiology, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Quantitative evaluation of several partial fourier reconstruction algorithms used in mriMagnetic Resonance in Medicine, 1993
- Projection Reconstruction Techniques for Reduction of Motion Effects in MRIMagnetic Resonance in Medicine, 1992
- Fast Spiral Coronary Artery ImagingMagnetic Resonance in Medicine, 1992
- Gradient moment nulling for steady‐state free precession MR imaging of cerebrospinal fluidMedical Physics, 1991
- Homodyne detection in magnetic resonance imagingIEEE Transactions on Medical Imaging, 1991