A fundamental limit on the performance of correlation based phase correction and flow estimation techniques
- 1 September 1994
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 41 (5) , 644-654
- https://doi.org/10.1109/58.308499
Abstract
Cross correlation and similar operations are used in ultrasonic imaging to estimate blood or soft tissue motion in one or more dimensions and to measure echo arrival time differences for phase aberration correction. These estimates are subject to large errors known as false peaks and smaller magnitude errors known as jitter. While false peaks can sometimes be removed through nonlinear processing, jitter errors place a fundamental limit on the performance of delay estimation techniques. This paper applies the Cramer-Rao Lower Bound to derive analytical expressions which predict the magnitude of jitter for 1-D and 2-D problems using both radio frequency (RF) and envelope detected data. One-dimensional simulation results are presented which closely match theoretical predictions. These results indicate that for typical clinical conditions axial jitter for detected data is approximately five times greater than that for RF data. Lateral jitter is approximately ten times greater than axial jitter for RF data. Examples are presented which utilize these results to predict the performance of phase aberration correction and flow estimation systems.<>Keywords
This publication has 22 references indexed in Scilit:
- Measurement of the complete (3D) velocity vector of blood flowsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- A real time system for quantifying and displaying two-dimensional velocities using ultrasoundUltrasound in Medicine & Biology, 1993
- A phase aberration correction method for ultrasound imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1993
- Range/velocity limitations for time-domain blood velocity estimationUltrasound in Medicine & Biology, 1993
- The van Cittert–Zernike theorem in pulse echo measurementsThe Journal of the Acoustical Society of America, 1991
- A novel method for angle independent ultrasonic imaging of blood flow and tissue motionIEEE Transactions on Biomedical Engineering, 1991
- A new wideband spread target maximum likelihood estimator for blood velocity estimation. I. TheoryIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1991
- Flow velocity profile via time-domain correlation: error analysis and computer simulationIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1990
- A New Velocity Estimator for Color Flow MappingPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1986
- Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation TechniquePublished by Institute of Electrical and Electronics Engineers (IEEE) ,1985