Breathing measurement reduces false-negative classification of tachypneic preextubation trial failures
- 1 June 1996
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 24 (6) , 976-980
- https://doi.org/10.1097/00003246-199606000-00017
Abstract
Objectives There is increased awareness of imposed work of breathing contributing to apparent ventilatory dependency. This study evaluates the impact of tachypnea as an indicator of ventilatory failure during a room air-5 cm H2 O continuous positive airway pressure, spontaneous breathing, preextubation trial when associated with increased imposed work of breathing. Design Prospective, descriptive, 1-yr data collection. Setting University hospital trauma intensive care unit (ICU). Patients Mechanically ventilated trauma ICU patients surviving to discharge. Intervention Patients were weaned to minimal mechanical ventilator support and underwent a 20-min room air-continuous positive airway pressure preextubation trial (FIO2 equals 0.21, continuous positive airway pressure equals 5 cm H2 O [0.5 kPa]). When passed (PaO2 more than equals 55 torr [more than equals 7.3 kPa], PaCO2 less than equals 45 torr [less than equals 6.0 kPa] with prior eucapnea, arterial pH more than equals 7.35, respiratory rate less than equals 30 breaths/min), extubation followed. If patients failed due to hypoxemia, ventilatory support resumed. If tachypnea was the reason for failure, work of breathing was measured. If patient work of breathing was less than equals 1.1 joule/L, extubation proceeded despite tachypnea. If patient work of breathing was more than 1.1 joule/L, imposed work of breathing was measured, and if residual ``physiologic'' work of breathing (patient work of breathing minus imposed work of breathing) was less than equals 0.8 joule/L, patients were extubated. Measurements and Main Results Of 589 extubations, 105 (18%) were classified as false negatives based on a preextubation rate of more than 30 breaths/min. Of these, 97 were successfully extubated despite tachypnea ranging from 32 to 56 breaths/min, when combined with either a patient work of breathing less than equals 1.1 joule/L or physiologic work of breathing less than equals 0.8 joule/L. The rate of extubation failure within 72 hrs was 7.8% (8/105) in the tachypneic group, compared with 7.9% (38/484) for those patients with a respiratory rate of less than equals 30 breaths/min. Some of the stimulus for the tachypnea was possibly due to increased imposed work of breathing, as the increased respiratory rate usually abated within 18 hrs after extubation. The reliance on a respiratory rate of less than equals 30 breaths/min as an absolute preextubation criterion would have resulted in a sensitivity of 82%, a specificity of 17%, a positive predictive value of 92%, a negative predictive value of 8%, and an overall accuracy of 77%. The average duration of mechanical ventilation during the study period decreased by 2 days, from 8.6 to 6.3 days (p equals .03). Conclusions Tachypnea as a marker of respiratory distress is sensitive, but is not sufficiently specific to be used as a criterion in preextubation trials. Reliance on tachypnea as a preextubation trial failure criterion is likely to prolong intubation and ventilatory support for a large number of patients. Patient risks, determined by the extubation failures and reintubation rate, are the same. (Crit Care Med 1996; 24:976-980)Keywords
This publication has 21 references indexed in Scilit:
- The Acute Respiratory Distress SyndromeNew England Journal of Medicine, 1995
- Components of the work of breathing and implications for monitoring ventilator-dependent patientsCritical Care Medicine, 1994
- FLOW RESISTIVE WORK CALCULATED BY THE CAMPBELL DIAGRAM IS AN ACCURATE PREDICTOR OF THE VENTILATOR SYSTEM IMPOSED WORK OF BREATHINGCritical Care Medicine, 1994
- ROOM AIR ABG ANALYSIS VS NON-INVASIVE GAS EXCHANGE MONITORING VS PULMONARY MECHANICS CRITERIA IN EXTUBATION FROM VENTILATOR SUPPORTCritical Care Medicine, 1993
- Imposed work of breathing and methods of triggering a demand-flow, continuous positive airway pressure systemCritical Care Medicine, 1993
- Weaning ParametersChest, 1992
- A Prospective Study of Indexes Predicting the Outcome of Trials of Weaning from Mechanical VentilationNew England Journal of Medicine, 1991
- Pressure Support Compensation for Inspiratory Work due to Endotracheal Tubes and Demand Continuous Positive Airway PressureChest, 1988
- PRESSURE SUPPORT, SIMV AND ASSIST CONTROL (A/C) DURING ACUTE RESPIRATORY FAILURE (ARF)Critical Care Medicine, 1986
- Evaluation of two different extubation criteriaCritical Care Medicine, 1986