Parametric analysis of flow in the intramyocardial circulation
- 1 July 1990
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 18 (4) , 347-365
- https://doi.org/10.1007/bf02364154
Abstract
A simple mathematical model of the intramyocardial circulation has been utilized to provide a better understanding of coronary blood flow. The model includes three myocardial layers, each characterized by a three-parameter windkessel with one capacitance and two resistances. The effects of the beating heart are taken into account by means of an intramyocardial pump and the possible collapse of the vessels by an elevated backpressure. The three basic parameters that govern the flow are a normalized time constant, \(\bar \tau \) , the total resistance, Rt, and a parameter, α, which specifies the resistance distribution in the intramyocardial circulation. Both the normal beating heart and prolonged diastole have been investigated analytically as well as numerically. It is shown that each of these parameters has its own special significance. Calculated pressure-flow relationships and zero-flow pressures for the case of prolonged diastole show a high sensitivity to \(\bar \tau \) and α.
Keywords
This publication has 17 references indexed in Scilit:
- Epicardial Coronary Blood Flow Including the Presence of Stenoses and Aorto-Coronary Bypasses—II: Experimental Comparison and Parametric InvestigationsJournal of Biomechanical Engineering, 1988
- Coronary pressure-flow relationships. Controversial issues and probable implications.Circulation Research, 1985
- Coronary diastolic pressure-flow relation and zero flow pressure explained on the basis of intramyocardial compliance.Circulation Research, 1985
- The role of vascular capacitance in the coronary arteries.Circulation Research, 1984
- Usefulness of Doppler Catheters in Assessment of Coronary Artery Blood FlowPublished by Springer Nature ,1983
- The effects of the coronary capacitance on the interpretation of diastolic pressure-flow relationships.Circulation Research, 1982
- Diastolic-systolic coronary flow differences are caused by intramyocardial pump action in the anesthetized dog.Circulation Research, 1981
- Characterization of the extravascular component of coronary resistance by instantaneous pressure-flow relationships in the dog.Circulation Research, 1979
- Diastolic coronary artery pressure-flow relations in the dog.Circulation Research, 1978
- Inhibition of coronary blood flow by a vascular waterfall mechanism.Circulation Research, 1975