Dose uniformity in scanned focused ultrasound hyperthermia
- 1 January 1994
- journal article
- research article
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 10 (6) , 775-784
- https://doi.org/10.3109/02656739409012370
Abstract
Scanned focused ultrasound (SFUS) is unique amongst noninvasive methods of inducing hyperthermia in that the absorbed power (SAR) distribution may be controlled at a scale of 0.5 cm or better. This high degree of spatial control of SAR implies that differences in local tissue cooling due to heterogeneity in perfusion, variations in the density of discrete thermally significant vessels and even local cooling around single large vessels may be compensated during SFUS treatments. In this paper we calculate thermal dose distributions arising from three different SFUS techniques: (1) the high-temperature short-duration (HTSD) ultrasound technique; (2) conventional systems employing a fixed scan and fixed SAR simulated by a uniform SAR; and (3) we optimize the SAR distribution using information from angiography and thermal models. These techniques are tested in the same anatomy having discrete vessels, a non-uniform vessel density and with little, if any, preheating of the incoming blood (i.e. the worst-case situation). The application of a uniform SAR to this volume resulted in a highly non-uniform thermal dose distribution. The situation is clearly improved in HTSD hyperthermia; however, the desired accuracy of positioning within the tumour is high, and to minimize background heating the focus must be stepped slowly and preferably in a semi-random pattern through the target volume. The third technique which employs spatial control over SAR resulted in the greatest uniformity in thermal dose. However, the use of this technique requires the input of the complete three-dimensional discrete vessel network and the availability of a tested three-dimensional discrete vessel thermal model.Keywords
This publication has 19 references indexed in Scilit:
- Temperature uniformity during hyperthermia: the impact of large vesselsPhysics in Medicine & Biology, 1992
- The effects of tissue heterogeneities and large blood vessels on the thermal exposure induced by short high-power ultrasound pulsesInternational Journal of Hyperthermia, 1992
- Early experience of a commercial scanned focused ultrasound hyperthermia systemInternational Journal of Hyperthermia, 1992
- Development of scanned focussed ultrasound hyperthermia: Clinical response evaluation clinical response evaluationInternational Journal of Radiation Oncology*Biology*Physics, 1991
- Optimization of the intensity gain of multiple-focus phased-array heating patternsInternational Journal of Hyperthermia, 1991
- Rapid heating: Critical theoretical assessment of thermal gradients found in hyperthermia treatmentsInternational Journal of Hyperthermia, 1991
- Time-temperature analysis of cell killing of BHK cells heated at temperatures in the range of 43.5°C to 57.0°CInternational Journal of Radiation Oncology*Biology*Physics, 1990
- Experimental verification of bioheat transfer theories: measurement of temperature profiles around large artificial vessels in perfused tissuePhysics in Medicine & Biology, 1990
- Effects of physical parameters on high temperature ultrasound hyperthermiaUltrasound in Medicine & Biology, 1990
- Quality assurance guidelines for ESHO protocolsInternational Journal of Hyperthermia, 1989