Effect of Antiarrhythmic Drug Therapy on the Incidence of Shocks in Patients who Receive an Implantable Cardioverter Defibrillator after a Single Episode of Sustained Ventricular Tachycardia/Fibrillation
- 1 November 1991
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 14 (11) , 1586-1592
- https://doi.org/10.1111/j.1540-8159.1991.tb02733.x
Abstract
Seventy‐four patients (16 women, 58 men, age 58 ± 21 years, mean ± standard deviation) who received an implantable Cardioverter de/ibrillator (ICD) after experiencing a single episode of ventricular tachycardia or ventricular fibrillation were followed to determine if antiarrhythmic drug therapy affects the incidence of ICD discharges. Thirty‐three patients (group A) were treated with an antiarrhythmic drug that was either untested or previously demonstrated during electropharmacological testing to be ineffective in suppressing the induction of ventricular tachycardia. Forty‐one patients (group B) were not treated with an antiarrhythmic drug. There were no significant differences between the two groups in regards to age, sex, incidence of coronary artery disease, left ventricular function or the type of ICD pulse generator used. During a mean follow‐up of 14 months for the entire cohort, 15 patients (46%) in group A and 18 patients (44%) in group B experienced at least one ICD shock. The time to the first appropriate shock (5 ± 5 months in both groups) and the frequency of ICD shocks (0.3 ± 0.2/month in group A vs 0.4 ± 0.5/month in group B) were similar in both groups. The incidence of syncope at the time of ICD discharge was higher in group A than group B patients (31% vs 5%, P < 0.05). In conclusion, antiarrhythmic drugs that are untested or have failed electropharmacological testing do not appear to reduce the probability of ICD discharge over a short‐term (mean 14 months) follow‐up in patients who have had only one clinical episode of VT/VF and may increase the risk of syncope during ICD discharge. Studies with a larger sample size and longer follow‐up period will be needed to confirm these findings.Keywords
This publication has 8 references indexed in Scilit:
- Time to first shock and clinical outcome in patients receiving an automatic implantable cardioverter-defibrillatorJournal of the American College of Cardiology, 1989
- Automatic Implantable Cardioverter Defibrillators and Survival of Patients with Left Ventricular Dysfunction and Malignant Ventricular ArrhythmiasAnnals of Internal Medicine, 1988
- Predictors of automatic implantable cardioverter defibrillator discharge for life-threatening ventricular arrhythmiasThe American Journal of Cardiology, 1988
- Electrophysiologic testing and follow-up of patients with aborted sudden deathJournal of the American College of Cardiology, 1987
- Is Programmed Stimulation of Value in Predicting the Long-Term Success of Antiarrhythmic Therapy for Ventricular Tachycardias?New England Journal of Medicine, 1986
- The Automatic Implantable Cardioverter-Defibrillator: Efficacy, Complications, and Device FailuresAnnals of Internal Medicine, 1986
- Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator.Circulation, 1985
- Management of recurrent ventricular tachycardia: Economic impact of therapeutic alternativesThe American Journal of Cardiology, 1984