Sequence specific visual detection of LAMP reactions by addition of cationic polymers
Open Access
- 10 January 2006
- journal article
- research article
- Published by Springer Nature in BMC Biotechnology
- Vol. 6 (1) , 3
- https://doi.org/10.1186/1472-6750-6-3
Abstract
Background: Development of a practical gene point-of-care testing device (g-POCT device) requires innovative detection methods for demonstrating the results of the gene amplification reaction without the use of expensive equipment. We have studied a new method for the sequence-specific visual detection of minute amounts of nucleic acids using precipitation reaction by addition of cationic polymers to amplicons of Loop mediated isothermal Amplification (LAMP). Results: Oligo DNA probes labeled with different fluorescent dyes were prepared for multiple nucleic acid templates, and the templates were amplified by the LAMP reactions under the existence of the probes. At completion of the LAMP reaction, an optimal amount of low molecular weight polyethylenimine (PEI) was added, resulting in the precipitation of the insoluble LAMP amplicon-PEI complex. The fluorescently labeled Oligo DNA probes hybridized to the LAMP product were incorporated into the precipitation, and the precipitate emitted fluorescence corresponding to the amplified nucleic acid templates. The color of emitted fluorescence can be detected easily by naked eye on a conventional UV illuminator. Conclusion: The presence or absence of minute amount of nucleic acid templates could be detected in a simple manner through visual assessment for the color of the LAMP amplicon-PEI complex precipitate. We conclude that this detection method may facilitate development of small and simple g-POCT device.Keywords
This publication has 15 references indexed in Scilit:
- Rapid sexing of bovine preimplantation embryos using loop-mediated isothermal amplificationTheriogenology, 2004
- Real-time turbidimetry of LAMP reaction for quantifying template DNAJournal of Biochemical and Biophysical Methods, 2004
- Development and Evaluation of a Novel Loop-Mediated Isothermal Amplification Method for Rapid Detection of Severe Acute Respiratory Syndrome CoronavirusJournal of Clinical Microbiology, 2004
- Real-Time Reverse Transcription Loop-Mediated Isothermal Amplification for Rapid Detection of West Nile VirusJournal of Clinical Microbiology, 2004
- Validation of the Loop-Mediated Isothermal Amplification Method for Single Nucleotide Polymorphism Genotyping with Whole BloodGenome Letters, 2003
- Low-molecular-weight polyethylenimine as a non-viral vector for DNA delivery: comparison of physicochemical properties, transfection efficiency and in vivo distribution with high-molecular-weight polyethylenimineJournal of Controlled Release, 2003
- Everyone's a (Future) ChemistScience, 2002
- Detection of Loop-Mediated Isothermal Amplification Reaction by Turbidity Derived from Magnesium Pyrophosphate FormationBiochemical and Biophysical Research Communications, 2001
- Precipitation of DNA by Polyamines: A Polyelectrolyte BehaviorBiophysical Journal, 1998
- Precipitation of Nucleic Acids with Poly (ethyleneimine)Biotechnology Progress, 1990