Determination of iron in blood serum using flow injection with luminol chemiluminescence detection
- 22 November 2004
- journal article
- Published by Wiley in Luminescence
- Vol. 19 (6) , 333-338
- https://doi.org/10.1002/bio.787
Abstract
A simple and rapid flow injection method is reported for the determination of iron in blood serum after acid digestion with HNO3 and HClO4, based on luminol CL detection in the absence of added oxidant. The detection limit (3 s) was 1.0 nmol/L with a sample throughput of 120/h. The calibration graph was linear over the range 0.001–1.0 µmol/L (r2 = 0.9974), with relative standard deviations (RSD) (n = 4) in the range 3.2–5%. The effect of interfering cations (Ca(II), Mg(II), Cu(II), Cd(II), Pb(II), Mn(II), Zn(II), Ni(II), Co(II) and Fe(III)) and anions (Cl−, SO42−, HCO3−, NO3−, NO2−) were studied using a luminol CL system for Fe(II) determination. The method was applied to normal blood serum and the results (1.32 ± 0.08–1.74 ± 0.05 mg/L) were compared with those from a spectrophotometric reference method (1.34 ± 0.06–1.80 ± 0.10 mg/L), which agree fairly well with the overall reference range in blood. Copyright © 2004 John Wiley & Sons, Ltd.Keywords
This publication has 14 references indexed in Scilit:
- Continuous shipboard determination of Fe(II) in polar waters using flow injection analysis with chemiluminescence detectionAnalytica Chimica Acta, 2002
- The kinetics and mechanism of oxidation of hydroxylamine by iron(iii)J. Chem. Soc., Dalton Trans., 2002
- Analytical applications of flow injection with chemiluminescence detection—a reviewLuminescence, 2001
- Multielement Profiling Analyses of Biological, Geochemical, and Environmental Samples as Studied by Analytical Atomic SpectrometryBulletin of the Chemical Society of Japan, 1999
- Accurate determination of iron, copper and zinc in human serum by isotope dilution analysis using double focusing ICP-MSJournal of Analytical Atomic Spectrometry, 1999
- Determination of sub-nanomolar levels of iron in seawater using flow injection with chemiluminescence detectionAnalytica Chimica Acta, 1998
- Rates and Mechanism of Fe(II) Oxidation at Nanomolar Total Iron ConcentrationsEnvironmental Science & Technology, 1995
- Stopped flow luminol chemiluminescence determination of Fe(II) and reducible iron in seawater at subnanomolar levelsMarine Chemistry, 1995
- Revised recommendations for the measurements of the serum iron in human bloodBritish Journal of Haematology, 1990
- Determination of trace amounts of iron(II) using chemiluminescence analysisAnalytical Chemistry, 1972