Skin protection against methylmethacrylate
- 1 January 1987
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 58 (3) , 236-238
- https://doi.org/10.3109/17453678709146473
Abstract
Ordinary surgical rubber gloves are penetrated by methylmethacrylate monomer (MMA) in less than 1 minute, as demonstrated by gas chromatographic measurements. A three-layered PVP glove, 0.07 mm thick - consisting of an outer layer of polyethylene, an intermediary layer of ethylene vinyl alcohol copolymer, and an inner layer of polyethylene - was impervious for 20 minutes, whereas a viton-butyl rubber glove, 0.27 mm thick, was impervious for 15 minutes. The PVP glove is recommended to orthopedic surgeons, nurses, and other handling acrylic bone cements to avoid sensitization, and is especially recommended to persons with known contact allergy to MMA.This publication has 9 references indexed in Scilit:
- Contact dermatitis to methyl methacrylateContact Dermatitis, 1984
- Surgical rubber gloves impervious to methylmethacrylate monomerActa Orthopaedica, 1984
- Permeability of Surgeons' Gloves to Methyl MethacrylateActa Orthopaedica, 1983
- Occupational Hazards of Acrylate Bone Cement in Orthopaedic SurgeryActa Orthopaedica, 1983
- Sensitizing potential of 14 mono (meth) acrylates in the guinea pig*Contact Dermatitis, 1982
- Contact dermatitis in surgeons from methylmethacrylate bone cementJournal of Bone and Joint Surgery, 1975
- Contact Dermatitis from Penetration of Rubber Gloves by Acrylic MonomerBMJ, 1971
- Allergic sensitization of the skin and oral mucosa to acrylic resin denture materialsThe Journal of Prosthetic Dentistry, 1956