Object. Clinical microdialysis enables monitoring of the cerebral extracellular chemistry of neurosurgical patients. Introduction of the technique into different hospitals' neurosurgical units has resulted in variations in the method of application. There are several variables to be considered, including length of the catheter membrane, type of perfusion fluid, flow rate of perfusion fluid, and on-line compared with delayed analysis of samples. The objects of this study were as follows: 1) to determine the effects of varying catheter characteristics on substance concentration; 2) to determine the relative recovery and true extracellular concentration by varying the flow rate and extrapolating to zero flow; and 3) to compare substance concentration obtained using a bedside enzyme analyzer with that of off-line high-performance liquid chromatography (HPLC).Methods. A specially designed bolt was used to conduct two adjacent microdialysis catheters into the frontal cortex of patients with head injury or poor-grade subarachnoid hemorrhage who were receiving ventilation. One reference catheter (10-mm membrane, perfused with Ringer's solution at 0.3 µl/minute) was constant for all studies. The other catheter was varied in terms of membrane length (10 mm or 30 mm), perfusion fluid (Ringer's solution or normal saline), and flow rate (0.1–1.5 µl/minute). The effect of freezing the samples on substance concentration was established by on-line analysis and then repeated analysis after storage at −70°C for 3 months. Samples assayed with the bedside enzyme analyzer were reassessed using HPLC for the determination of glutamate concentrations.Conclusions. Two adjacent microdialysis catheters that were identical in membrane length, perfusion fluid, and flow rate showed equivalent results. Variations in perfusion fluid and freezing and thawing of samples did not result in differences in substance concentration. Catheter length had a significant impact on substance recovery. Variations in flow rate enabled the relative recovery to be calculated using a modification of the extrapolation-to-zero-flow method. The recovery was approximately 70% at 0.3 µl/minute and 30% at 1 µl/minute (10-mm membrane) for all analytes. Glutamate results obtained with the enzyme analyzer showed good correlation with those from HPLC.Keywords
This publication has 29 references indexed in Scilit:
- Cerebral microdialysis combined with single-neuron and electroencephalographic recording in neurosurgical patientsJournal of Neurosurgery, 1999
- Increase in extracellular glutamate caused by reduced cerebral perfusion pressure and seizures after human traumatic brain injury: a microdialysis studyJournal of Neurosurgery, 1998
- Neurochemical monitoring using intracerebral microdialysis in patients with subarachnoid hemorrhageJournal of Neurosurgery, 1996
- Intracerebral Microdialysis of Glutamate and Aspartate Two Vascular Territories after Aneurysmal Subarachnoid HemorrhageNeurosurgery, 1996
- Intracerebral Microdialysis of Extracellular Amino Acids in the Human Epileptic FocusJournal of Cerebral Blood Flow & Metabolism, 1992
- Microdialysis—principles and applications for studies in animals and manJournal of Internal Medicine, 1991
- Microdialysis sampling of the neuronal environment in basic and clinical researchJournal of Internal Medicine, 1991
- Microdialysis in the human brain: Extracellular measurements in the thalamus of parkinsonian patientsLife Sciences, 1990
- Intracerebral microdialysis: a new method in applied clinical neuroscience researchBritish Journal Of Neurosurgery, 1990
- Determination of Brain Interstitial Concentrations by MicrodialysisJournal of Neurochemistry, 1989