Artificial Liver
- 1 June 1992
- journal article
- Published by Wiley in Artificial Organs
- Vol. 16 (3) , 235-242
- https://doi.org/10.1111/j.1525-1594.1992.tb00303.x
Abstract
Without transplantation, approximately 90% of patients with fulminant hepatic failure die. If patients receive a liver transplant, there is often a lag between the need for and the availability of a donor liver. Therefore, there is a definite need for a liver support system to support the patient's own liver function in fulminant hepatic failure and while awaiting transplantation. We have developed an artificial liver system that not only eliminates lipophilic toxins such as phenols, fatty acids, and mercaptans, but also hydrophilic ones such as ammonia. This artificial liver system consists of a monitor, an extracorporeal blood circuit that uses a hydrophilic polysulfone high-flux dialyzer to remove water-soluble metabolites, and a novel hydrophilic liquid membrane filter to remove lipophilic toxins. In more than 100 in vitro experiments using porcine (5 I) blood, the system was evaluated for its ability to remove toxins that are normally increased in hepatic failure. We found that phenol, cresol, and short- and medium-chain fatty acids can be almost completely eliminated from the blood within 5 h. In animal experiments using pigs, we also found no significant changes of blood gases, liver parameters, electrolytes, and blood cell counts.Keywords
This publication has 12 references indexed in Scilit:
- On the Role of Free Phenols in the Blood of Patients in Hepatic FailurePublished by Springer Nature ,1981
- Hemofiltration in Acute Liver Failure: Substition with Electrolyte Solution Versus Normal Animal UltrafiltratePublished by Springer Nature ,1981
- Hormone Losses by Charcoal HemoperfusionPublished by Springer Nature ,1981
- Albumin‐Coated Amberlite XAD‐7 Resin for Hemoperfusion in Acute Liver Failure: Part II: In Vivo EvaluationArtificial Organs, 1979
- The Application of Immobilized Enzymes in an Artificial Liver Support SystemArtificial Organs, 1979
- Carrier-Bound Detoxifying Enzymes for an Extracorporeal Detoxification of Endogenous and Exogenous ToxinsPublished by Springer Nature ,1978
- Refixation of Solubilized and Purified Microsomal Enzymes: Towards an Extracorporal Detoxification in Liver FailurePublished by Springer Nature ,1978
- HÆMOPERFUSIONS OVER MICROENCAPSULATED ADSORBENT IN A PATIENT WITH HEPATIC COMAThe Lancet, 1972
- PROBLEMS OF FULMINANT HEPATIC FAILUREBritish Medical Bulletin, 1972
- PLASMAPHERESIS IN HEPATIC COMAThe Lancet, 1967