Electrochemical Immunosensors for the Simultaneous Detection of Two Tumor Markers
- 1 February 2005
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (5) , 1496-1502
- https://doi.org/10.1021/ac0485278
Abstract
The microfabrication of electrochemical immunosensors for the simultaneous detection of two protein analytes is described. The sensors consisted of two iridium oxide electrodes (1-mm diameter) patterned on a glass substrate. Capture antibodies were immobilized on the porous iridium oxide electrodes by covalent attachment using (3-aminopropyl)triethoxysilane and glutaraldehyde. The spatial separation of the electrodes (2.5 mm) enabled simultaneous electrochemical immunoassays to be conducted without cross-talk between the electrodes. Proteins were measured using electrochemical ELISA, and detection was achieved by electrochemically oxidizing alkaline phosphatase-generated hydroquinone. Sensors for the simultaneous detection of goat IgG and mouse IgG, and for the tumor markers CEA and AFP, were developed. The sensors had detection limits of 1, 2, 1.2, and 1 ng/mL for goat IgG, mouse IgG, CEA, and AFP, respectively.Keywords
This publication has 10 references indexed in Scilit:
- Hydroquinone diphosphate: an alkaline phosphatase substrate that does not produce electrode fouling in electrochemical immunoassaysBiosensors and Bioelectronics, 2004
- Novel amperometric immunosensors based on iridium oxide matricesBiosensors and Bioelectronics, 2004
- Electrochemical Protein Chip with Arrayed Immunosensors with Antibodies Immobilized in a Plasma-Polymerized FilmAnalytical Chemistry, 2003
- Feasibility studies of simultaneous multianalyte amperometric immunoassay based on spatial resolutionJournal of Pharmaceutical and Biomedical Analysis, 1999
- Multianalyte immunoanalysis: practical aspects of manufacturing transducersBiosensors and Bioelectronics, 1997
- Covalent attachment of functionalized lipid bilayers to planar waveguides for measuring protein binding to biomimetic membranesProtein Science, 1995
- A multichannel immunochemical sensor for determination of 2,4-dichlorophenoxyacetic acidAnalytica Chimica Acta, 1995
- Novel nonseparation sandwich-type electrochemical enzyme immunoassay system for detecting marker proteins in undiluted bloodClinical Chemistry, 1995
- Metal Filmed-Semiconductor Photoelectrochemical CellsJournal of the Electrochemical Society, 1980
- Chemically modified tin oxide electrodeAnalytical Chemistry, 1975