Does the laryngeal mask airway compromise cricoid pressure?
Open Access
- 1 October 1992
- journal article
- Published by Wiley in Anaesthesia
- Vol. 47 (10) , 829-831
- https://doi.org/10.1111/j.1365-2044.1992.tb03138.x
Abstract
Summary: The laryngeal mask airway was inserted in 10 cadavers. At postmortem the chest was opened and an infusion set primed with a dilute barium solution was inserted into the oesophagus and ligated in place. A cricoid force of 43 N was then applied and the infusion set was positioned so that when the clamp was opened it generated a pressure of 7.8 kPa within the oesophagus. The cricoid pressure was able to stop the flow of fluid into the oesophagus. This demonstrates that cricoid pressure is effective in preventing reflux at intragastric pressures which are encountered clinically and the presence of the laryngeal mask airway does not compromise this.Keywords
This publication has 6 references indexed in Scilit:
- The use of the fibreoptic laryngoscope to confirm the position of the laryngeal maskAnaesthesia, 1989
- Anaesthesia for emergency Caesarean section using the Brain laryngeal airwayAnaesthesia, 1989
- THE LARYNGEAL MASK—A NEW CONCEPT IN AIRWAY MANAGEMENTBritish Journal of Anaesthesia, 1983
- The determination of an effective cricoid pressureAnaesthesia, 1983
- CHANGES IN INTRAGASTRIC PRESSURE FOLLOWING THE ADMINISTRATION OF SUXAMETHONIUMBritish Journal of Anaesthesia, 1962
- CRICOID PRESSURE TO CONTROL REGURGITATION OF STOMACH CONTENTS DURING INDUCTION OF ANÆSTHESIAThe Lancet, 1961