The detection system for atomic absorption spectrometers based on the use of photomultiplier tubes (PMTs) is analysed from the point of view of its ability to provide accurate analytical information. It is shown that absorbance recorded by the system depends not only on the number of absorbing atoms but also on their distribution in the furnace volume. The typical non-uniformity of atomic distribution that occurs in graphite furnaces and its impact on the recorded signal are discussed. The cross-sectional distribution of the intensity of the radiation beam from a primary source was measured at different locations of the spectrometer for different source operating conditions. The distribution is rather non-uniform and can be described by the Gaussian function. An analysis of the joint effect of the radiation and analyte non-uniformity on the absorbance measured is given. The shape of the radiation beam cross-section changes from a circle to an ellipse with increasing lamp current. A new detection system based on the use of a solid-state detector (photodiode array, charge coupled device, charge injection device) instead of PMTs is proposed. The solid-state detector is located vertically along the monochromator exit slit and allows the detection of spatially resolved absorbances. It is shown that the analytical signal recorded by this new system is proportional to the number of absorbing atoms irrespective of the non-uniformities described above.Keywords
This publication has 16 references indexed in Scilit:
- Shadow spectral filming: a method of investigating electrothermal atomization. Part 3. Dynamics of longitudinal propagation of an analyte within graphite furnacesJournal of Analytical Atomic Spectrometry, 1993
- Concentration curves in atomic absorption spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1992
- Shadow spectral fiming: a method of investigating electrothermal atomization. Part 2. Dynamics of formation and structure of the absorption layer of aluminium, indium and gallium moleculesJournal of Analytical Atomic Spectrometry, 1992
- Topology and vaporization characteristics of palladium, cobalt, manganese, indium, and aluminum on a graphite surface using electrothermal atomic absorptionAnalytical Chemistry, 1991
- Shadow spectral filming: a method of investigating electrothermal atomization. Part 1. Dynamics of formation and structure of the absorption layer of thallium, indium, gallium and aluminium atomsJournal of Analytical Atomic Spectrometry, 1991
- Recent advances in absolute analysis by graphite furnace atomicabsorption spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1990
- Existence of microdroplets and dispersed atoms on the graphite surface in electrothermal atomizersAnalytical Chemistry, 1987
- Spatially resolved absorbance profiles detailing the selenium vaporisation process in electrothermal atomisersJournal of Analytical Atomic Spectrometry, 1987
- Time and spatial absorbance profiles within a graphite furnace atomizerSpectrochimica Acta Part B: Atomic Spectroscopy, 1982
- Optical system for gathering simultaneous time and spatial data from transient eventsAnalytical Chemistry, 1979