Essential problems in quantification of proteins following colloidal staining with Coomassie Brilliant Blue dyes in polyacrylamide gels, and their solution
- 1 January 1990
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 11 (2) , 101-117
- https://doi.org/10.1002/elps.1150110202
Abstract
Quantitative determination of stained proteins following polyacrylamide gel electrophoresis (PAGE) is of increasing interest especially since computer‐aided densitometers have become available as well as recipes for sensitive and background‐free staining with Coomassie Brilliant Blue dyes. However, avoidance of separation artifacts is not the only essential prerequisite for quantitative evaluation. The local particle density of a protein in a given gel is of critical importance since it determines its stainability. Depending on local protein concentration, the dye binding to the same amount of a given protein differs considerably. Since the stainability of proteins using colloidal staining procedures, as with Coomassie Brilliant Blue dyes, is time‐dependent and, in addition, also dependent on the pore size of a given polyacrylamide gel used for PAGE, calibration curves for quantitative determinations have to be prepared in polyacrylamide gels of the same composition as used for PAGE. Staining conditions also have to be identical for calibration gels and gels under analysis. If, however, a set of calibration curves is prepared for different staining times, it is possible to calculate a generalized calibration curve, allowing for quantitative evaluation with flexible staining time. Furthermore, and in consequence of the implications due to particle density, quantitative determination via densitometry is only possible by determining the protein amount of each single measuring point (pixel) via its absorbance on the basis of a calibration curve. Since the particle density is inherent in a calibration curve, the final summation of the protein amount per pixel will give values close to reality.This publication has 25 references indexed in Scilit:
- Quantitative densitometry from the point of view of information theoryElectrophoresis, 1990
- Improved staining of proteins in polyacrylamide gels including isoelectric focusing gels with clear background at nanogram sensitivity using Coomassie Brilliant Blue G‐250 and R‐250Electrophoresis, 1988
- Microelectrophoresis in the differential diagnosis of proteinuric diseasesElectrophoresis, 1986
- Fast silver staining of polyacrylamide gels at elevated temperaturesElectrophoresis, 1986
- Improved design of one-dimensional vertical polyacrylamide slab gel electrophoresis avoids lateral streakingElectrophoresis, 1985
- Clear background and highly sensitive protein staining with Coomassie Blue dyes in polyacrylamide gels: A systematic analysisElectrophoresis, 1985
- Improved procedure for silanization of glass plates as supports for polyacrylamide gelsElectrophoresis, 1984
- Visualization of proteins with a silver “stain”: A critical analysisElectrophoresis, 1981
- One‐ and two‐dimensional electrophoresis in micro‐slab gelsElectrophoresis, 1980
- A Simple, Versatile, Sensitive and Volume-Independent Method for Quantitative Protein Determination which is Independent of Other External InfluencesHoppe-Seyler´s Zeitschrift Für Physiologische Chemie, 1979