Differential effects of eight metal ions on lymphocyte differentiation antigens in vitro
- 1 August 1990
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 24 (8) , 1059-1068
- https://doi.org/10.1002/jbm.820240808
Abstract
In vitro studies were conducted to determine the effects of metal ions known to be released from metallic implants in vivo on the expression of lymphocyte surface antigens. Normal human peripheral blood lymphocytes were exposed to various concentrations of metal ions (Fe3+, Ni2+, Co2+, Mo6+, V5+, Cr6+, Cr3+, and Ti3+) for 30 min at 37°C in a 5% CO2 atmosphere, and then analyzed for their ability to form rosettes with sheep red blood cells. Following this preliminary analysis, lymphocytes were exposed to the metal ions found to inhibit the E‐rosette reaction (Fe3+, Ni2+, and Co2+) in order to determine which of the following surface antigens were affected: CD2, CD3, CD4, CD8, CD1, CD22, CD10, and HLA‐DR. Our results showed that the in vitro treatment of lymphocytes with Fe3+ or Co2+ caused inhibition of CD2 only, whereas Ni2+ caused inhibition of both CD2 and CD3 antigens. These findings suggest that Fe3+, Co2+, and Ni2+ ions may interfere with T cell activation since both CD2 and CD3 are involved in that process.This publication has 31 references indexed in Scilit:
- Direct and indirect nickel‐specific stimulation of T lymphocytes from patients with allergic contact dermatitis to nickelEuropean Journal of Immunology, 1988
- Comparison of NiSO4 and NiCl2 as Sensitizers in the Guinea PigInternational Archives of Allergy and Immunology, 1988
- The in vivo performance of 250 internal fixation devices: a follow-up studyBiomaterials, 1987
- Blood distribution of nickel, cobalt, and chromium following intramuscular injection into hamstersJournal of Biomedical Materials Research, 1984
- Release of cobalt and nickel from a new total finger joint prosthesis made of vitalliumJournal of Biomedical Materials Research, 1983
- Serum concentrations of chromium, cobalt and nickel after total hip replacement: a six month studyBiomaterials, 1983
- Urinary Cobalt Levels in Patients with Porous Austin-Moore ProsthesesPublished by Wolters Kluwer Health ,1983
- Metal Determination in Organic Fluids of Patients with Stainless Steel Hip ArthroplastyActa Orthopaedica, 1983
- Monoclonal antibodies OKT 11 and OKT 11A have pan‐T reactivity and block sheep erythrocyte “receptors”European Journal of Immunology, 1982
- Hair sampling for chromium content following Charnley hip arthroplastyJournal of Biomedical Materials Research, 1976