Physicochemical Characteristics of Antimony Microelectrode with Special Reference to Selection of Standard Buffers
- 1 January 1980
- journal article
- research article
- Published by Physiological Society of Japan in The Japanese Journal of Physiology
- Vol. 30 (4) , 509-528
- https://doi.org/10.2170/jjphysiol.30.509
Abstract
Antimony (Sb) microelectrodes with tips of 2 to 5 .mu.m in outside diameter were constructed, and their electromotive forces (EMF) were tested in response to the pH of several calibration buffers. The data were compared with those of glass pH electrodes. Increasing ionic strength (I) caused a significant deviation in pH readings of the Sb-microelectrode (.delta.pHSb-Glass). Even with the correction for ionic strength, the values of .DELTA.pHSb-Glass were dependent on the nature of calibration buffers employed. Among various buffers, Tris buffer [Tris(hydroxymethyl)aminomethane(THAM)] had the least disturbance on the Sb-microelectrode, and bicarbonate had also relatively minor effect. The pH value according to the Sb-electrode was caused to deviate considerably by phosphate. The effect of phosphate within the range of 1 to 67 mM can be predicted by 1/.DELTA.pHSb-Glass = 1 + (0.174/[PO4]). Like phosphate, BES [N, N-Bis (2-hydroxyethyl)-2-aminoethanesulfonic acid] also had a significant effect on the EMF of the Sb-microelectrode. Upon consideration of the above facts, measurements of several biological fluids such as those of the in vivo pH of intratubular fluid of bullfrog kidney were carried out with the Sb-microelectrode calibrated by 90 mM Tris buffer. The Sb-microelectrode when properly calibrated can be used for the pH measurement of ultraminute amounts of biological samples.This publication has 7 references indexed in Scilit:
- General Properties of Antimony Microelectrode in Comparison with Glass Microelectrode for pH MeasurementThe Japanese Journal of Physiology, 1980
- Measurement of Intracellular pH of Bullfrog Skeletal Muscle and Renal Tubular Cells with Double-Barreled Antimony MicroelectrodesMembrane Biochemistry, 1980
- Manufacture and utilization of antimony pH electrodesKidney International, 1978
- Seasonal Change of Membrane Potential across the Proximal Tubular Epithelium in Bullfrog KidneysThe Japanese Journal of Physiology, 1978
- The influence of carbon dioxide, bicarbonate and other buffers on the potential of antimony microelectrodesPflügers Archiv - European Journal of Physiology, 1977
- Localization of urine acidification in the mammalian kidneyAmerican Journal of Physiology-Legacy Content, 1960
- THE SITE OF ACIDIFICATION OF THE URINE WITHIN THE RENAL TUBULE IN AMPHIBIAAmerican Journal of Physiology-Legacy Content, 1936