Quantitative volume flow estimation using velocity profiles
- 1 May 1994
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 41 (3) , 340-345
- https://doi.org/10.1109/58.285468
Abstract
The direct measurement of the velocity profile of blood flowing in a vessel yields a volume flow estimate that is more accurate than single-point Doppler ultrasound. A volume flow estimate is made by assuming a circularly symmetric velocity field and integrating the velocity profile measured along a diameter. The many velocity measurements made contribute to higher precision in the integrated velocity estimate. Also, the velocity profile furnishes the functional diameter of the vessel at many points through the cardiac cycle. This algorithm, as implemented on the Philips CVI system, was tested theoretically by numerical modelling, and experimentally with a flow simulator. The effect of beamwidth, vessel size, and measurement position misalignment on the volume flow estimate were studied. Experimental and theoretical results agreed well and showed that the flow estimation algorithm can produce precise and accurate volume flow estimates. The flow estimate is sensitive to the flow angle and is inaccurate by 5% per degree error in the angle. Beamwidths of 1.0 to 1.5 mm are a good match to axial resolution and yield accurate volume flow estimates in vessels over 2 mm in diameter. Larger beamwidths give lower volume flow estimates, but are not as sensitive to misalignment.<>Keywords
This publication has 9 references indexed in Scilit:
- A velocity evaluation phantom for colour and pulsed doppler instrumentsUltrasound in Medicine & Biology, 1992
- Computer-controlled positive displacement pump for physiological flow simulationMedical & Biological Engineering & Computing, 1991
- Flow Estimation Using Ultrasound Imaging (Color M-Mode) and Computer PostprocessingJournal of Cerebral Blood Flow & Metabolism, 1991
- Volumetric blood flow via time-domain correlation: experimental verificationIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1990
- Flow velocity profile via time-domain correlation: error analysis and computer simulationIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1990
- A Review of Doppler Flow Mapping TechniquesPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1987
- Time Domain Formulation of Pulse-Doppler Ultrasound and Blood Velocity Estimation by Cross CorrelationUltrasonic Imaging, 1986
- Measurement of blood flow by ultrasound: Accuracy and sources of errorUltrasound in Medicine & Biology, 1985
- Topoflow - A digital full range Doppler velocity meterIEEE Transactions on Sonics and Ultrasonics, 1978