Randomised, controlled trial of nasal continuous positive airway pressure in the extubation of infants weighing 600 to 1250 g
Open Access
- 1 July 1998
- journal article
- clinical trial
- Published by BMJ in Archives of Disease in Childhood: Fetal & Neonatal
- Vol. 79 (1) , F54-F57
- https://doi.org/10.1136/fn.79.1.f54
Abstract
AIM To determine whether extubation to nasal continuous airway pressure (NCPAP) results in a greater proportion of infants remaining free of additional ventilatory support for one week after extubation compared with those extubated directly to headbox oxygen. METHODS A randomised, controlled, clinical trial was conducted at the neonatal intensive care unit of the Royal Women’s Hospital, Melbourne, of infants with birthweights between 600 and 1250 g, ventilated via an endotracheal tube for more than 12 hours, requiring less than 50% oxygen, a ventilator rate ⩽ 20/minute, considered by the clinical management team to be ready for extubation. Infants were randomly allocated either to NCPAP or to oxygen administered via a headbox. Success was defined by no requirement for additional ventilatory support over the week following extubation. Failure criteria were (i) apnoea; (ii) absolute increase in oxygen requirement greater than 15% above that required before extubation; or (iii) respiratory acidosis (pH6.67 kPa). RESULTS Thirty one of 47 (66%) infants were successfully extubated to NCPAP compared with 18 of 45 (40%) for headbox oxygen. The increase in failure rate in the headbox group was due primarily to increased oxygen requirements in this group. Of the 27 who failed headbox oxygen, 26 were given a trial of NCPAP and 13 did not require endotracheal reintubation. There was no significant difference between the groups in the total number of days of assisted ventilation or the duration of inpatient stay. CONCLUSIONS NCPAP applied prophylactically after endotracheal extubation reduces the incidence of adverse clinical events that lead to failure of extubation in the seven days after extubation. This reduction is clinically important. The benefits of NCPAP do not seem to be associated with an increased incidence of unwanted side effects.Keywords
This publication has 12 references indexed in Scilit:
- Application of nasal continuous positive airway pressure to early extubation in very low birthweight infants.Archives of Disease in Childhood: Fetal & Neonatal, 1995
- Does continuous positive airway pressure (CPAP) during weaning from intermittent mandatory ventilation in very low birth weight infants have risks or benefits? A controlled trialPediatric Pulmonology, 1995
- Randomized, controlled trial of nasopharyngeal continuous positive airway pressure in the extubation of very low birth weight infantsThe Journal of Pediatrics, 1994
- Randomised trial of methods of extubation in acute and chronic respiratory distress.Archives of Disease in Childhood, 1993
- Nasal Continuous Positive Airway Pressure Facilitates Extubation of Very Low Birth Weight NeonatesPediatrics, 1991
- Effects on respiration of CPAP immediately after extubation in the very preterm infantPediatric Pulmonology, 1988
- Continuous positive airway pressure via a single nasal catheter in preterm infantsEarly Human Development, 1985
- Postextubation Nasal Continuous Positive Airway PressureAmerican Journal of Diseases of Children, 1982
- Incidence and evolution of subependymal and intraventricular hemorrhage: A study of infants with birth weights less than 1,500 gmThe Journal of Pediatrics, 1978
- Treatment of the Idiopathic Respiratory-Distress Syndrome with Continuous Positive Airway PressureNew England Journal of Medicine, 1971