3D acquisition and reconstruction in positron emission tomography
- 1 September 1992
- journal article
- research article
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 6 (3) , 123-130
- https://doi.org/10.1007/bf03178303
Abstract
3D positron emission tomography (PET) refers to an acquisition geometry and recon-struction procedure that allows all coincidence events within the solid angle of the tomograph to be recorded and subsequently reconstructed. The reconstruction algorithm must consider the angle of each coincidence event relative to the central axis of the scanner. The aim of the technique is to maximise the sensitivity of the system by utilising all events that it is possible to record from the object. Conventional cylindrical 2D PET systems typically detect ∼0.4%–0.5% of decaying nuclei within the field of view; with a 3D system this can increase to over 3%. Reconstruction in 3D using filtered-backprojection techniques has been developed and provides results that show little degradation of physical characteristics compared with 2D systems, apart from an increased scatter event rate. 3D techniques may be used to (i) improve data quality using currently acceptable doses of radioactivity and scanning times; (ii) extend the scanning period for short-lived tracers, especially11C-labeled ligands; or, conversely (iii) decrease injected doses of radiotracer or reduce scanning times to achieve similar results as those using current methods in 2D.Keywords
This publication has 20 references indexed in Scilit:
- Fully three-dimensional reconstruction for a PET camera with retractable septaIEEE Transactions on Medical Imaging, 1991
- Implementation of three-dimensional image reconstruction for multi-ring positron tomographsPhysics in Medicine & Biology, 1990
- Three-dimensional image reconstruction from complete projectionsPhysics in Medicine & Biology, 1989
- Three dimensional reconstruction of PET data from a multi-ring cameraIEEE Transactions on Nuclear Science, 1989
- Analytic 3D image reconstruction using all detected eventsIEEE Transactions on Nuclear Science, 1989
- An evaluation of a two-dimensional array detector for high resolution PETIEEE Transactions on Medical Imaging, 1988
- A positron tomograph with 600 BGO crystals and 2.6 mm resolutionIEEE Transactions on Nuclear Science, 1988
- A Multicrystal Two Dimensional BGO Detector System for Positron Emission TomographyIEEE Transactions on Nuclear Science, 1986
- Fully-three-dimensional positron emission tomographyPhysics in Medicine & Biology, 1980
- Three-dimensional Reconstruction from Radiographs and Electron Micrographs: Application of Convolutions instead of Fourier TransformsProceedings of the National Academy of Sciences, 1971