A Long-Term in Vivo Bone Strain Measurement Device
- 1 January 1989
- journal article
- research article
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 2 (2) , 195-206
- https://doi.org/10.3109/08941938909015351
Abstract
Bone remodeling resulting from implant insertion has been attributed to changes in the bone's strain state. Since remodeling takes several months, it was this study's purpose to develop a long-term in vivo strain sensor. Porous surfaced metal tabs were attached to a standard strain gauge. Two standard gauges and the porous tabbed gauge were attached to one femur and three standard gauges to the contralateral femur of a greyhound. Tissue ingrowth provided an attachment mechanism for the porous tabbed gauge in vivo. Gauge measurements were compared to those from the standard gauges. Post sacrifice testing allowed further comparisons. After histo-logical preparation the femoral section shapes as well as the gauge locations were examined and photographed. The porous tabbed gauge remained bonded and sensed strain throughout the 8-week implantation period, while the standard gauges debonded and were unable to detect strain after 3 weeks. During testing, the measurements from the porous tabbed gauge were lower than those from the standard gauges. This was consistent with the histology which indicated that fibrous tissue had invaded the gauge's porous surface. Although the use of tissue ingrowth as an attachment mechanism seems to be worthwhile, a means of insuring bone ingrowth is necessary.Keywords
This publication has 16 references indexed in Scilit:
- The effect of proximally and fully porous‐coated canine hip stem design on bone modelingJournal of Orthopaedic Research, 1987
- Mechanically adaptive bone remodellingJournal of Biomechanics, 1982
- In vivo strain gage implantation in ratsJournal of Biomechanics, 1982
- A study of bone remodeling using metal-polymer laminatesJournal of Biomedical Materials Research, 1981
- The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of BoneClinical Orthopaedics and Related Research, 1980
- The Effect of Porous Surface Configuration on the Tensile Strength of Fixation of Implants by Bone IngrowthClinical Orthopaedics and Related Research, 1980
- Bone ingrowth and stress shielding with a porous surface coated fracture fixation plateJournal of Biomedical Materials Research, 1979
- A method for direct recording of electromechanical data from skeletal bone in living animalsJournal of Biomechanics, 1974
- Implantation of strain gages on bone in vivoJournal of Biomechanics, 1972
- Porous titanium surgical implant materialsJournal of Biomedical Materials Research, 1971