Passive and Active Inspired Gas Humidification in Infants and Children
- 1 September 1989
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 71 (3) , 350-354
- https://doi.org/10.1097/00000542-198909000-00006
Abstract
The hypothesis that both active and passive airway humidification prevents hypothermia in infants and children, but that neither decreases the duration of postoperative recovery was tested. Twenty-seven ASA physical status 1 or 2 patients were studied who weighed between 5 and 30 kg, underwent superficial operation, were anesthetized with halothane and 70% N2O and whose lungs were ventilated via a Rees modification of an Ayre''s t-piece. The children were randomly assigned to receive active airway humidification and warming using an MR450 Servo airway heater and humidifier set at 37.degree.C (n = 10), passive airway humidification using the Humid-Vent 1 heat and moisture exchanger placed between the Ayre''s t-piece and the endotracheal tube (n = 8), or no airway humdification and heating (control, n = 9). Distal tracheal and tympanic membrane temperatures and airway humidity were recorded during the first 90 min of surgery. Rectal temperature was measured during the postanesthetic recovery period. Relative humidity of inspired respiratory gases was approximately 30% in the control group and approximately 90% in the group given active airway humidification. Initial inspired humidity in the passive humidification group (50%) increased to approximately 80%, a level not significantly different from that in the active group after 80 min of anesthesia. Central body temperature increased 0.25.degree.C during active active airway humidification and heating, whereas temperature decreased 0.25.degree.C during passive humidification and 0.75.degree.C without airway humidification. Distal tracheal temperature was significantly higher in the groups given passive and active humidification than in the control group. Recovery was rapid in all patients and did not correlate with the type of humidification. Heat and moisture exchangers are less effective than active heating and humidification but significantly better than no humidification.This publication has 7 references indexed in Scilit:
- The Thermoregulatory Threshold in Humans during Nitrous Oxide-Fentanyl AnesthesiaAnesthesiology, 1988
- The Thermoregulatory Threshold in Humans during Halothane AnesthesiaAnesthesiology, 1988
- HEAT AND MOISTURE EXCHANGERS IN ARTIFICIAL VENTILATIONBritish Journal of Anaesthesia, 1987
- Peroperative HypothermiaActa Anaesthesiologica Scandinavica, 1984
- Humidity and Temperature Changes during Low Flow and Closed System AnaesthesiaActa Anaesthesiologica Scandinavica, 1981
- The regulation of $$Pa_{CO_2 } $$ during controlled ventilation of children with a T-pieceCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1979
- Humidity and the Anesthetized PatientAnesthesiology, 1979