Intra‐Aortic Balloon Pumping: Theory and Practice Experience with 325 Patients
- 1 August 1978
- journal article
- research article
- Published by Wiley in Artificial Organs
- Vol. 2 (3) , 249-256
- https://doi.org/10.1111/j.1525-1594.1978.tb03461.x
Abstract
Intra‐aortic balloon pumping to support the failing circulation is now an accepted therapeutic modality. The device is simple. Insertion can be accomplished rapidly and efficiently in emergency rooms, coronary care units, cardiac catheterization suites and operating rooms, preoperatively, intraoperatively and postoperatively. The hemodynamic effects are immediate and predictable, and the accruing clinical results show increasing survival and hospital discharge rates. In these institutions, mechanical support of the circulation by this and more advanced methods has been formalized within the responsibility of a Circulatory Support Service.The purpose of this Report is to summarize some observations and analyses which have been made during care of 325 consecutive postcardiotomy and/or postinfarction cardiogenic shock patients. Historical, theoretical, basic, and applied aspects and current results are included. Foremost are the straightforward concepts of considering the heart as a pump, the failing heart as a failing pump and intra‐aortic balloon pumping as a temporary intravascular, auxiliary pump, capable of stabilizing or reversing that failure if utilized early in its evolution.Keywords
This publication has 15 references indexed in Scilit:
- TOTAL SUPPORT OF THE CIRCULATION OF A PATIENT WITH POST-CARDIOTOMY STONE-HEART SYNDROME BY A PARTIAL ARTIFICIAL HEART (ALVAD) FOR 5 DAYS FOLLOWED BY HEART AND KIDNEY TRANSPLANTATIONPublished by Elsevier ,1978
- Results and complications of intraaortic balloon pumping in surgical and medical patientsThe American Journal of Cardiology, 1977
- Intraaortic Balloon PumpingThe Annals of Thoracic Surgery, 1976
- Intraaortic Balloon AssistanceThe Annals of Thoracic Surgery, 1976
- Absolute determination of cardiac output in intra-aortic balloon pumped patients using the radial arterial pressure trace.Circulation, 1976
- Intraaortic Balloon Counterpulsation: A Review of Physiological Principles, Clinical Results, and Device SafetyThe Annals of Thoracic Surgery, 1974
- Clinical and Hemodynamic Results of Intraaortic Balloon Pumping and Surgery for Cardiogenic ShockCirculation, 1972
- Observations on Factors Affecting Local Forces in the Left Ventricular Wall during Acute Myocardial IschemiaCirculation Research, 1971
- Alteration of mechanical performance of the ventricle by intraaortic balloon counterpulsationThe American Journal of Cardiology, 1970
- Diastolic balloon pumping (with carbon dioxide) in the aorta—A mechanical assistance to the failing circulationAmerican Heart Journal, 1962