Signal Enhancement in HPLC/Microcoil NMR Using Automated Column Trapping
- 13 September 2006
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (20) , 7154-7160
- https://doi.org/10.1021/ac0605748
Abstract
A new HPLC NMR system is described that performs analytical separation, preconcentration, and NMR spectroscopy in rapid succession. The central component of our method is the online preconcentration sequence that improves the match between postcolumn analyte peak volume and microcoil NMR detection volume. Separated samples are collected on to a C18 guard column with a mobile phase composed of 90% D2O/10% acetonitrile-D3 and back-flushed to the NMR microcoil probe with 90% acetonitrile-D3/10% D2O. To assess the performance of our unit, we separated a standard mixture of 1 mM ibuprofen, naproxen, and phenylbutazone using a commercially available C18 analytical column. The S/N measurements from the NMR acquisitions indicated that we achieved signal enhancement factors up to 10.4 (±1.2)-fold. Furthermore, we observed that preconcentration factors increased as the injected amount of analyte decreased. The highest concentration enrichment of 14.7 (±2.2)-fold was attained injecting 100 μL of solution of 0.2 mM (∼4 μg) ibuprofen.Keywords
This publication has 41 references indexed in Scilit:
- Microcoil nuclear magnetic resonance spectroscopyJournal of Pharmaceutical and Biomedical Analysis, 2005
- Nuclear magnetic resonance coupled microseparationsMagnetic Resonance in Chemistry, 2005
- Phytochemistry in the microgram domain—a LC–NMR perspectiveMagnetic Resonance in Chemistry, 2005
- The design of an on‐line semi‐preparative LC–SPE–NMR system for trace analysisMagnetic Resonance in Chemistry, 2005
- Comparative Analysis of a Neurotoxin from Calliostoma canaliculatum by On-Line Capillary Isotachophoresis/H NMR and Diffusion 1H NMRJournal of Natural Products, 2005
- Characterization of a paracetamol metabolite using on-line LC-SPE-NMR-MS and a cryogenic NMR probeJournal of Chromatography A, 2004
- Application of solid‐phase extraction coupled to an NMR flow‐probe in the analysis of HPLC fractionsMagnetic Resonance in Chemistry, 2001
- High-Resolution NMR Spectroscopy of Sample Volumes from 1 nL to 10 μLChemical Reviews, 1999
- Optimization of LC-NMR. III—Increased signal-to-noise ratio through column trappingMagnetic Resonance in Chemistry, 1998
- Direct-coupling of FT-NMR to high performance liquid chromatography.Proceedings of the Japan Academy, Series B, 1978