COBAS AmpliPrep-COBAS TaqMan Hepatitis B Virus (HBV) Test: a Novel Automated Real-Time PCR Assay for Quantification of HBV DNA in Plasma
- 1 March 2007
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 45 (3) , 828-834
- https://doi.org/10.1128/jcm.00914-06
Abstract
Success in antiviral therapy for chronic hepatitis B is supported by highly sensitive PCR-based assays for hepatitis B virus (HBV) DNA. Nucleic acid extraction from biologic specimens is technically demanding, and reliable PCR results depend on it. The performances of the fully automatic system COBAS AmpliPrep-COBAS TaqMan 48 (CAP-CTM; Roche, Branchburg, NJ) for HBV DNA extraction and real-time PCR quantification were assessed and compared to the endpoint PCR COBAS AMPLICOR HBV monitor (CAHBM; Roche). Analytical evaluation with a proficiency panel showed that CAP-CTM quantitated HBV DNA levels in one single run over a wide dynamic range (7 logs) with a close correlation between expected and observed values (r = 0.976, interassay variability below 5%). Clinical evaluation, as tested with samples from 92 HBsAg-positive patients, demonstrated excellent correlation with CAHBM (r = 0.966, mean difference in quantitation = 0.36 log(10) IU/ml). CAP-CTM detected 10% more viremic patients and longer periods of residual viremia in those on therapy. In lamivudine (LAM)-resistant patients, the reduction of HBV DNA after 12 months of Adefovir (ADF) was higher in the combination (LAM+ADF) schedule than in ADF monotherapy (5.1 logs versus 3.5 logs), suggesting a benefit in continuing LAM. CAP-CTM detected HBV DNA in liver biopsy samples from 15% of HBsAg-negative, anti-HBcAg-positive graft donors with no HBV DNA in plasma. The amount of intrahepatic HBV DNA was significantly lower in occult HBV infection than in overt disease. CAP-CTM can improve the management of HBV infection and the assessment of antiviral therapy and drug resistance, supporting further insights in the emerging area of occult HBV infection.Keywords
This publication has 42 references indexed in Scilit:
- Fully automated quantitation of Hepatitis B virus (HBV) DNA in human plasma by the COBAS® AmpliPrep/COBAS® TaqMan® System☆, ☆☆Journal of Clinical Virology, 2006
- Evaluation of the COBAS AmpliPrep-Total Nucleic Acid Isolation-COBAS TaqMan Hepatitis B Virus (HBV) Quantitative Test and Comparison to the VERSANT HBV DNA 3.0 AssayJournal of Clinical Microbiology, 2006
- The first one thousand liver transplants in Turin: a single-center experience in ItalyTransplant International, 2005
- Virologic response and resistance to adefovir in patients with chronic hepatitis BJournal of Hepatology, 2005
- Dynamic Range and Reproducibility of Hepatitis B Virus (HBV) DNA Detection and Quantification by Cobas Taqman HBV, a Real-Time Semiautomated AssayJournal of Clinical Microbiology, 2005
- Evaluation of the COBAS TaqMan 48 Real-Time PCR System for Quantitation of Hepatitis B Virus DNAJournal of Clinical Microbiology, 2005
- Real-Time PCR Assay Using Molecular Beacon for Quantitation of Hepatitis B Virus DNAJournal of Clinical Microbiology, 2004
- Fully Automated, Internally Controlled Quantification of Hepatitis B Virus DNA by Real-Time PCR by Use of the MagNA Pure LC and LightCycler InstrumentsJournal of Clinical Microbiology, 2004
- Real-time quantitation of hepatitis B virus (HBV) DNA in tumorous and surrounding tissue from patients with hepatocellular carcinomaJournal of Medical Virology, 2002
- De novo hepatitis B after liver transplantation from hepatitis B core antibody—Positive donors in an area with high prevalence of anti-HBc positivity in the donor populationLiver Transplantation, 2001