Comparison of two waist-mounted and two ankle-mounted electronic pedometers
- 13 August 2005
- journal article
- research article
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 95 (4) , 335-343
- https://doi.org/10.1007/s00421-005-0018-3
Abstract
This study compared two ankle-mounted pedometers [StepWatch 3 (SW-3Ankle) and Activity Monitoring Pod 331 (AMPAnkle)] and two waist-mounted pedometers [New Lifestyles NL-2000 (NLWaist) and Digiwalker SW-701 (SW-701Waist)] under controlled and free-living conditions. In part I, 20 participants walked on a treadmill at speeds of 27–107 m min−1. Actual steps were counted with a hand counter. In part II, participants performed leg swinging, heel tapping, stationary cycling, and car driving. In part III, 15 participants wore all pedometers for a 24 h period. The SW-3Ankle displayed values that were within 1% of actual steps during treadmill walking at all speeds. The other devices underestimated steps at slow speeds but all gave mean values that were within ±3% of actual steps at 80 m min−1 and above. The SW-3Ankle registered some steps during heel tapping, leg swinging, and cycling, while the AMPAnkle was only responsive to leg swinging. During car driving no devices recorded more than eight steps, on average. Over 24 h, the AMPAnkle recorded 18% fewer steps than the SW-3Ankle (PWaist and the NLWaist recorded 15 and 11% less than the SW-3Ankle, respectively (NSD). The SW-3Ankle has superior accuracy at slow treadmill walking speeds (although it was also more likely to detect “fidgeting” activities). Over 24 h, the SW-3Ankle tended to give higher estimates of steps per day than the other ankle- and waist-mounted pedometers.Keywords
This publication has 31 references indexed in Scilit:
- Ability of Different Physical Activity Monitors to Detect Movement During Treadmill WalkingInternational Journal of Sports Medicine, 2003
- Utility of Pedometers for Assessing Physical ActivitySports Medicine, 2002
- The relationship between pedometer-determined ambulatory activity and body composition variablesInternational Journal of Obesity, 2001
- Methodological Considerations for Researchers and Practitioners Using Pedometers to Measure Physical (Ambulatory) ActivityResearch Quarterly for Exercise and Sport, 2001
- Active living: On the Road with the 10,000 Stepssm ProgramJournal of the American Dietetic Association, 2000
- Step activity monitor: Increased accuracy in quantifying ambulatory activityJournal of Orthopaedic Research, 1999
- Lifestyle physical activity interventions: History, short- and long-term effects, and recommendationsPublished by Elsevier ,1998
- Daily Walking Combined With Diet Therapy Is a Useful Means for Obese NIDDM Patients Not Only to Reduce Body Weight But Also to Improve Insulin SensitivityDiabetes Care, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Physical fitness and incidence of hypertension in healthy normotensive men and womenJAMA, 1984