NUCLEAR MAGNETIC MOMENT OF SCANDIUM OF MASS 45
- 1 November 1951
- journal article
- Published by Canadian Science Publishing in Canadian Journal of Physics
- Vol. 29 (6) , 463-469
- https://doi.org/10.1139/p51-049
Abstract
By the method of nuclear magnetic resonance, the magnetic moment of Sc45 (without diamagnetic correction) is found to be 4.74916 ± 0.00012. The correction is +0.00717 with unknown and possibly large error. The equipment designed to search for magnetic resonance by varying the field of the magnet is described, with special emphasis on the magnet current regulator.Keywords
This publication has 8 references indexed in Scilit:
- On the Magnetic Moments of , , , , andPhysical Review B, 1950
- A Radiofrequency Spectrograph and Simple Magnetic-Field MeterReview of Scientific Instruments, 1950
- A Magnetic Field Strength Meter Using the Proton Magnetic MomentReview of Scientific Instruments, 1949
- Nuclear InductionPhysical Review B, 1946
- Internal Diamagnetic FieldsPhysical Review B, 1941
- Über das magnetische Moment des ScandiumkernesThe European Physical Journal A, 1937
- Das Kernmoment des Scandiums (Sc45)The Science of Nature, 1934
- Über das Kernmoment des ScandiumsThe European Physical Journal A, 1934