Abstract
A simple and rapid method has been developed to simultaneously measure sub-microg/L quantities of the oxyhalide anions bromate, chlorate, iodate, and perchlorate in water samples. Water samples (10 mL) are passed through barium and hydronium cartridges to remove sulfate and carbonate, respectively. The method utilizes the direct injection of 10 microL volumes of water samples into a liquid chromatography-tandem triple-quadrupole mass spectrometry (LC-MS/MS) system. Ionization is accomplished using electrospray ionization in negative mode. The method detection limits were 0.021 microg/L for perchlorate, 0.045 microg/L for bromate, 0.070 microg/L for iodate, and 0.045 microg/L for chlorate anions in water. The LC-MS/MS method described here was compared to established EPA methods 300.1 and 317.1 for bromate analysis and EPA method 314.0 for perchlorate analysis. Samples collected from sites with known contamination were split and sent to certified laboratories utilizing EPA methods for bromate and perchlorate analysis. At concentrations above the reporting limits for EPA methods, the method described here was always within 20% of the established methods, and generally within 10%. Twenty-one commercially available bottled waters were analyzed for oxyhalides. The majority of bottled waters contained detectable levels of oxyhalides, with perchlorate < or = 0.74 microg/L, bromate < or = 76 microg/L, iodate < or = 25 microg/ L, and chlorate < or = 5.8 microg/L. Perchlorate, iodate, and chlorate were detectable in nearly all natural waters tested, while bromate was only detected in treated waters. Perchlorate was found in several rivers and reservoirs where itwas not found previously using EPA 314.0 (reporting limit of 4 microg/L). This method was also applied to common detergents used for cleaning laboratory glassware and equipmentto evaluate the potential for sample contamination. Only chlorate appeared as a major oxyhalide in the detergents evaluated, with concentrations up to 517 microg/g. Drinking water treatment plants were also evaluated using this method. Significant formations of chlorate and bromate are demonstrated from hypochlorite generation and ozonation. From the limited data set provided here, it appears that perchlorate is a ubiquitous contaminant of natural waters at trace levels.Keywords
This publication has 24 references indexed in Scilit:
- Analysis of Perchlorate in Water and Soil by Electrospray LC/MS/MSAnalytical Chemistry, 2003
- Analysis of Endocrine Disruptors, Pharmaceuticals, and Personal Care Products in Water Using Liquid Chromatography/Tandem Mass SpectrometryAnalytical Chemistry, 2003
- The Toxicology of Iodate: A Review of the LiteratureThyroid®, 2001
- Subchronic Sodium Chlorate Exposure in Drinking Water Results in a Concentration-Dependent Increase in Rat Thyroid Follicular Cell HyperplasiaToxicologic Pathology, 2001
- Determination of nanomolar levels of perchlorate in water by ESI-FAIMS-MSJournal of Analytical Atomic Spectrometry, 2000
- Does Perchlorate in Drinking Water Affect Thyroid Function in Newborns or School-Age Children?Journal of Occupational and Environmental Medicine, 2000
- Analysis of Perchlorate in Groundwater by Electrospray Ionization Mass Spectrometry/Mass SpectrometryEnvironmental Science & Technology, 2000
- Simultaneous determination of bromide, bromate and nitrite in low μg l−1 levels by ion chromatography without sample pretreatmentWater Research, 1999
- Quantitation of perchlorate ion by electrospray ionization mass spectrometry (ESI-MS) using stable association complexes with organic cations and bases to enhance selectivityJournal of Analytical Atomic Spectrometry, 1999
- High selective determination of bromate in ozonized water by using ion chromatography with postcolumn derivatization equipped with reagent preparation deviceAnalytica Chimica Acta, 1997