Comparison of the Hinge Flow Fields of Two Bileaflet Mechanical Heart Valves under Aortic and Mitral Conditions
- 1 December 2004
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 32 (12) , 1607-1617
- https://doi.org/10.1007/s10439-004-7814-5
Abstract
Background: Animal and clinical studies have shown that bileaflet mechanical heart valve designs are plagued by thromboembolic complications, with higher rates in the mitral than in the aortic position. This study evaluated the hinge flow dynamic of the 23 mm St. Jude Medical (SJM) Regent and the 23 mm CarboMedics (CM) valves under aortic conditions and compared these results with previous findings under mitral conditions. Method: Velocity and Reynolds shear stress fields were captured using two-component laser Doppler velocimetry. Results: Under aortic conditions, both the SJM and CM hinge flow fields exhibited a strong forward flow pattern during systole (maximum velocities of 2.31 and 1.75 m/s, respectively) and two main leakage jets during diastole (maximum velocities of 3.08 and 2.27 m/s, respectively). Conclusions: Aortic and mitral flow patterns within the two hinges were similar, but with a more dynamic flow during the forward flow phase under aortic conditions. Velocity magnitudes and shear stresses measured under mitral conditions were generally higher than those obtained in the aortic position, which may explain the higher rates of thromboembolism in the mitral implants when compared with the aortic implants.Keywords
This publication has 9 references indexed in Scilit:
- An in vitro assessment by means of laser Doppler velocimetry of the medtronic advantage bileaflet mechanical heart valve hinge flowThe Journal of Thoracic and Cardiovascular Surgery, 2003
- Microflow fields in the hinge region of the CarboMedics bileaflet mechanical heart valve designThe Journal of Thoracic and Cardiovascular Surgery, 2002
- A reevaluation and discussion on the threshold limit for hemolysis in a turbulent shear flowJournal of Biomechanics, 2001
- An In Vitro Study of the Hinge and Near-Field Forward Flow Dynamics of the St. Jude Medical® Regent™ Bileaflet Mechanical Heart ValveAnnals of Biomedical Engineering, 2000
- A comparison of the hinge and near-hinge flow fields of the St Jude medical hemodynamic plus and regent bileaflet mechanical heart valvesThe Journal of Thoracic and Cardiovascular Surgery, 2000
- Frequency and severity of intravascular hemolysis after left-sided cardiac valve replacement with medtronic hall and St. Jude medical prostheses, and influence of prosthetic type, position, size and numberThe American Journal of Cardiology, 1993
- Pivot Design in Bileaflet ValvesAsaio Journal, 1992
- “Shear induced platelet activation” - A critical reappraisalBiorheology, 1985
- Human red blood cell hemolysis in a turbulent shear flow: Contribution of Reynolds shear stressesBiorheology, 1984