Microvascular Assessment of Burn Depth Conversion during Varying Resuscitation Conditions
- 1 November 2001
- journal article
- Published by Oxford University Press (OUP) in Journal of Burn Care & Rehabilitation
- Vol. 22 (6) , 406-416
- https://doi.org/10.1097/00004630-200111000-00011
Abstract
Conversion of partial- to full-thickness injuries, even after the burning has stopped, remains a significant clinical problem. We developed a rat model with a wide range of burn depths to study this phenomenon by microvascular assessment. Fifty-four male Sprague-Dawley rats weighing 460 g on average were studied. Real-time tissue monitoring of pH, paCO2, and paO2 was achieved by placement of a continuous blood gas monitor transducer in the aorta. Ten, 2-cm x 2-cm burns were created on each animal with milled aluminum templates (100 degrees C) with varying contact times. Conversion of burn depth in these wounds was documented by serial laser Doppler imager scanning over a 5-hour period. Animals received Ringer's lactate resuscitation at 0, 2, 4, 6, and 8 ml/kg/%burn. Serial laser Doppler scanning directly demonstrated progressive loss of perfusion to partial-thickness burns dependent upon the amount of fluid resuscitation. Conversion of partial- to full-thickness burns in this rat model (documented by laser Doppler microvascular assessment) was dependent upon how the animals were resuscitated.Keywords
This publication has 12 references indexed in Scilit:
- The use of laser Doppler imaging as an aid in clinical management decision making in the treatment of vesicant burnsBurns, 1998
- Use of Laser Doppler Flowmetry for Estimation of the Depth of BurnsPlastic and Reconstructive Surgery, 1998
- Serum Lactate and Base Deficit Suggest Inadequate Resuscitation of Patients with Burn Injuries: Application of a Point-of-Care Laboratory InstrumentJournal of Burn Care & Rehabilitation, 1997
- New laser doppler scanner, a valuable adjunct in burn depth assessmentBurns, 1993
- Looking at burn wounds: The A. B. Wallace Memorial Lecture 1991Burns, 1992
- Elucidating the Vascular Response to Burns with a New Rat ModelPublished by Wolters Kluwer Health ,1992
- Adequate resuscitation of burn patients may not be measured by urine output and vital signsCritical Care Medicine, 1991
- Burn Depth Estimation—Man or MachinePublished by Wolters Kluwer Health ,1984
- Fluid Resuscitation for Extensively Burned PatientsPublished by Wolters Kluwer Health ,1981
- Guidelines For Fluid ResuscitationPublished by Wolters Kluwer Health ,1981