Role of Microvolt T-Wave Alternans in Assessment of Arrhythmia Vulnerability Among Patients With Heart Failure and Systolic Dysfunction
- 11 November 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 118 (20) , 2022-2028
- https://doi.org/10.1161/circulationaha.107.748962
Abstract
Background— Sudden cardiac death remains a leading cause of mortality despite advances in medical treatment for the prevention of ischemic heart disease and heart failure. Recent studies showed a benefit of implantable cardioverter defibrillator implantation, but appropriate shocks for ventricular tachyarrhythmias were noted only in a minority of patients during 4 to 5 years of follow-up. Accordingly, better risk stratification is needed to optimize patient selection. In this regard, microvolt T-wave alternans (TWA) has emerged as a potentially useful measure of arrhythmia vulnerability, but it has not been evaluated previously in a prospective, randomized trial of implantable cardioverter defibrillator therapy. Methods and Results— This investigation was a prospective substudy of the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) that included 490 patients at 37 clinical sites. TWA tests were classified by blinded readers as positive (37%), negative (22%), or indeterminate (41%) by standard criteria. The composite primary end point was the first occurrence of any of the following events: sudden cardiac death, sustained ventricular tachycardia/fibrillation, or appropriate implantable cardioverter defibrillator discharge. During a median follow-up of 30 months, no significant differences in event rates were found between TWA-positive or -negative patients (hazard ratio 1.24, 95% confidence interval 0.60 to 2.59, P=0.56) or TWA-negative and nonnegative (positive and indeterminate) subjects (hazard ratio 1.28, 95% confidence interval 0.65 to 2.53, P=0.46). Similar results were obtained with the inclusion or exclusion of patients randomized to amiodarone in the analyses. Conclusions— TWA testing did not predict arrhythmic events or mortality in SCD-HeFT, although a small reduction in events (20% to 25%) among TWA-negative patients cannot be excluded given the sample size of this study. Accordingly, these results suggest that TWA is not useful as an aid in clinical decision making on implantable cardioverter defibrillator therapy among patients with heart failure and left ventricular systolic dysfunction.Keywords
This publication has 34 references indexed in Scilit:
- Microvolt T-Wave Alternans for Arrhythmia Risk Stratification in Left Ventricular Dysfunction: Which Patients Benefit?Journal of the American College of Cardiology, 2007
- Predictive Value of Microvolt T-Wave Alternans in Patients With Left Ventricular DysfunctionJournal of the American College of Cardiology, 2007
- Effect of bundle branch block on microvolt T-wave alternans and electrophysiologic testing in patients with ischemic cardiomyopathyHeart Rhythm, 2007
- “Indeterminate” Microvolt T-Wave Alternans Tests Predict High Risk of Death or Sustained Ventricular Arrhythmias in Patients With Left Ventricular DysfunctionJournal of the American College of Cardiology, 2006
- Microvolt T-Wave Alternans and the Risk of Death or Sustained Ventricular Arrhythmias in Patients With Left Ventricular DysfunctionJournal of the American College of Cardiology, 2006
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionNew England Journal of Medicine, 2002
- A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1999
- The Effect of Procainamide on T Wave AlternansJournal of Cardiovascular Electrophysiology, 1999
- T Wave Alternans During Exercise and Atrial Pacing in HumansJournal of Cardiovascular Electrophysiology, 1997
- Nonparametric Estimation from Incomplete ObservationsJournal of the American Statistical Association, 1958