Limits of Recognition for Simple Vapor Mixtures Determined with a Microsensor Array
- 5 March 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (7) , 1885-1895
- https://doi.org/10.1021/ac035294w
Abstract
The “limit of recognition” (LOR) has been defined as the minimum concentration at which reliable individual vapor recognition can be achieved with a multisensor array, and methodology for determining the LORs of individual vapors probabilistically on the basis of sensor array response patterns has been reported. This article explores the problems of defining and evaluating LORs for vapor mixtures in terms of the absolute and relative component vapor concentrations, where the mixture must be discriminated from those component vapors and from the subset of possible lower-order component mixtures. Monte Carlo simulations and principal components regression analyses of an extant database of calibrated responses to a set of 16 vapors from an array of 6 diverse polymer-coated surface acoustic wave sensors are used to illustrate the approach and to examine trends in LOR values among the 120 possible binary mixtures and 560 possible ternary mixtures in the data set. At concentrations exceeding the LOD, 89% of the binary mixtures could be reliably recognized (<5% error) over some composite concentration range, while only 3% of the ternary mixtures could be recognized. Most binary mixtures could be recognized only if the constituent vapor relative concentration ratio, defined in terms of multiples of the LOD for each vapor, was ≤20. Correlations with the Euclidean distance(s) separating the normalized constituent vapor response vectors allow reasonably accurate predictions of the limiting recognizable mixture composition ranges for binary and ternary cases. Results are considered in the context of using microsensor arrays for vapor detection and recognition in microanalytical systems.Keywords
This publication has 36 references indexed in Scilit:
- Analysis of solvent vapors in breath and ambient air with a surface acoustic wave sensor arrayAnnals of Occupational Hygiene, 2001
- In AC Research: In AC ResearchPublished by American Chemical Society (ACS) ,2001
- Conferring Selectivity to Chemical Sensors via Polymer Side-Chain Selection: Thermodynamics of Vapor Sorption by a Set of Polysiloxanes on Thickness-Shear Mode ResonatorsAnalytical Chemistry, 2000
- Development of a NASICON-based amperometric carbon dioxide sensorSensors and Actuators B: Chemical, 2000
- Quantitative RP-HPLC Determination of Some Aldehydes and Hydroxyaldehydes as Their 2,4-Dinitrophenylhydrazone DerivativesAnalytical Chemistry, 1998
- Analyzing organic vapors in exhaled breath using a surface acoustic wave sensor array with preconcentration: Selection and characterization of the preconcentrator adsorbentAnalytica Chimica Acta, 1998
- Rapid Analyte Recognition in a Device Based on Optical Sensors and the Olfactory SystemAnalytical Chemistry, 1996
- Effects of Temperature and Humidity on the Performance of Polymer-Coated Surface Acoustic Wave Vapor Sensor ArraysAnalytical Chemistry, 1996
- Characterization of polymeric surface acoustic wave sensor coatings and semiempirical models of sensor responses to organic vaporsAnalytical Chemistry, 1993
- Extended disjoint principal-components regression analysis of SAW vapor sensor-array responsesSensors and Actuators B: Chemical, 1993