Broadband ultrasound attenuation signals depend on trabecular orientation: An in vitro study
- 1 July 1993
- journal article
- Published by Springer Nature in Osteoporosis International
- Vol. 3 (4) , 185-191
- https://doi.org/10.1007/bf01623674
Abstract
Quantitative ultrasound (QUS) techniques have recently been introduced as alternative methods free of ionizing radiation for non-invasive assessment of skeletal status in osteoporosis. We carried out an in vitro study on bone specimens to investigate whether broadband ultrasound attenuation (BUA) signals are associated with bone structure, specifically with the orientation of the trabeculae, and whether this association is independent of the association between orientation and bone mineral density (BMD) as measured by dual-energy X-ray absorptiometry (DXA). BUA and BMD of 10 cubical specimens of purely trabecular bovine bone were examined along the three principal axes. The relative orientation of the trabeculae with respect to the direction of the ultrasound beam was evaluated on high-resolution conventional radiographs employing a semiquantitative ALIGNMENT score ranging from −2 (for perpendicular) to +2 (parallel). BUA variability was 27.6 dB/MHz, reflecting both inter-specimen (18.2 dB/MHz) and intra-specimen (19.4 dB/MHz) variability at comparable levels and to a much lesser extent reproducibility errors (1 dB/MHz). BUA was 44%–54% larger along the axis of the compressive trabeculae as compared with the two perpendicular axes. BMD and ALIGNMENT showed independent significant associations with BUA. A change in ALIGNMENT from perpendicular to parallel corresponded to a difference in BUA of 36.1 dB/MHz. The substantial level of intra-specimen variability suggests that BUA reflects anisotropical characteristics of trabecular bone. The association of BUA and ALIGNMENT indicates that BUA signals depend on trabecular orientation. This association is independent of BMD, indicating that BUA has considerable potential for non-invasive assessment of bone structure and strength, free of ionizing radiation, and for complementing existing bone densitometry examinations.Keywords
This publication has 40 references indexed in Scilit:
- Measurement of mechanical properties of bone material in vitro by ultrasound reflection: Methodology and comparison with ultrasound transmissionJournal of Bone and Mineral Research, 1991
- Comparison of the trabecular and cortical tissue moduli from human iliac crestsJournal of Orthopaedic Research, 1989
- Osteoporotic bone fragility. Detection by ultrasound transmission velocityJAMA, 1989
- In vitro comparison of quantitative computed tomography and broadband ultrasonic attenuation of trabecular boneBone, 1989
- Age and bone mass as predictors of fracture in a prospective study.Journal of Clinical Investigation, 1988
- On the dependence of the elasticity and strength of cancellous bone on apparent densityJournal of Biomechanics, 1988
- Comparison of broadband ultrasonic attenuation of the os calcis and quantitative computed tomography of the distal radiusClinical Physics and Physiological Measurement, 1987
- Biomechanical competence of vertebral trabecular bone in relation to ash density and age in normal individualsBone, 1987
- Elastic properties of cancellous bone: Measurement by an ultrasonic techniqueJournal of Biomechanics, 1987
- Generalized Theory of Acoustic Propagation in Porous Dissipative MediaThe Journal of the Acoustical Society of America, 1962